Biodegradable intrascleral implant for sustained intraocular delivery of betamethasone phosphate.

Okabe Junko, Kimura Hideya, Kunou Noriyuki, Okabe Komei, Kato Aki, Ogura Yuichiro

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To evaluate the feasibility of using a biodegradable intrascleral implant for intraocular sustained delivery of betamethasone phosphate (BP).

METHODS

The intrascleral implant (0.5 mm thick and 4 mm in diameter) was made of poly(DL-lactide) containing 25% betamethasone phosphate. The in vitro release of BP from the implant was evaluated by high-performance liquid chromatography (HPLC). The implants were placed into a scleral pocket in the rabbit's eye. The concentrations of BP in the aqueous humor, vitreous, and retina-choroid were measured by HPLC. The toxicity and biocompatibility of the implant were evaluated by slit lamp examination, electroretinography, and light microscopy.

RESULTS

In vitro studies demonstrated that the implants released BP in a biphasic pattern for at least 8 weeks. The BP concentrations in the vitreous and the retina-choroid remained within the concentration range capable of suppressing inflammatory responses for more than 8 weeks. The BP concentration was greater in the retina-choroid than in the vitreous. In the aqueous humor, BP was below the detection limit during the observation period. No significant toxicity to the retina was observed. Also, the implant showed good biocompatibility in the eye.

CONCLUSIONS

These results suggest that the intrascleral implant would be a promising system for delivery of steroid to the posterior segment of the eye.

Для цитирования: Okabe Junko, Kimura Hideya, Kunou Noriyuki, Okabe Komei, Kato Aki, Ogura Yuichiro. Biodegradable intrascleral implant for sustained intraocular delivery of betamethasone phosphate.. Investigative ophthalmology & visual science. 2003. DOI: 10.1167/iovs.02-0375.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.