Composition of volatile organic compounds in diathermy plume as detected by selected ion flow tube mass spectrometry.

Moot Andrew R, Ledingham Katherine M, Wilson Paul F, Senthilmohan Senti T, Lewis David R, Roake Justin, Allardyce Randall

СтатьяПеревод в очереди

Аннотация

BACKGROUND

There is some evidence that surgical plume may pose a risk to health professionals, but the risks posed by volatile organic compounds have not been thoroughly investigated.

METHODS

The composition of volatile organic compounds in diathermy plume produced during surgery was analysed by selected ion flow tube mass spectrometry.

RESULTS

Hydrogen cyanide (3-51 parts per million), acetylene (2-8 parts per million), and 1,3-butadiene (0.15-0.69 parts per million) were identified in the plume.

CONCLUSION

Although there is no evidence of adverse health effects from the volatile organic compound in diathermy plume, the evidence that it is safe to breathe this plume is lacking. Therefore, we would recommend the use of smoke evacuators where practical.

Для цитирования: Moot Andrew R, Ledingham Katherine M, Wilson Paul F, Senthilmohan Senti T, Lewis David R, Roake Justin, Allardyce Randall. Composition of volatile organic compounds in diathermy plume as detected by selected ion flow tube mass spectrometry.. ANZ journal of surgery. 2007. DOI: 10.1111/j.1445-2197.2006.03827.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.