Heart rate variability analysis is more sensitive at identifying neonatal sepsis than conventional vital signs.

Bohanon Fredrick J, Mrazek Amy A, Shabana Mohamed T, Mims Sarah, Radhakrishnan Geetha L, Kramer George C, Radhakrishnan Ravi S

Clinical StudyСтатьяПоддержка NIH: внешняя программаПоддержка правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Sepsis remains the largest preventable source of neonatal mortality in the world. Heart rate variability (HRV) analysis and noninvasive cardiac output have been shown to be useful adjuncts to sepsis detection in many patient groups.

METHODS

With Institutional Review Board approval, 4 septic and 6 nonseptic extremely low birth weight patients were enrolled. Data from septic and healthy patients were collected for 5 hours. Electrocardiogram waveform and traditional vital signs were collected and the RR intervals were calculated; then HRV analysis was performed in both the time and frequency domain.

RESULTS

HRV measurements in time domain, heart rate, and pulse oximetry (SpO2) were significantly different in septic patients vs nonseptic controls.

CONCLUSIONS

These results indicate that nonconventional vital signs such as HRV are more sensitive than traditionally used vital signs, such as cardiac output and mean arterial pressure, in the confirmation of sepsis in extremely low birth weight neonates. HRV may allow for earlier identification of septic physiology.

Для цитирования: Bohanon Fredrick J, Mrazek Amy A, Shabana Mohamed T, Mims Sarah, Radhakrishnan Geetha L, Kramer George C, Radhakrishnan Ravi S. Heart rate variability analysis is more sensitive at identifying neonatal sepsis than conventional vital signs.. American journal of surgery. 2015. DOI: 10.1016/j.amjsurg.2015.06.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.