A novel system of four-dimensional motion analysis after total hip arthroplasty.

Hagio Keisuke, Sugano Nobuhiko, Nishii Takashi, Miki Hidenobu, Otake Yoshito, Hattori Asaki, Suzuki Naoki, Yonenobu Kazuo, Yoshikawa Hideki, Ochi Takahiro

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

We have developed a novel system of four-dimensional motion analysis after total hip arthroplasty (THA) that can aid in preventing dislocation by assessing safe range of motion for patients in several daily activities. This system uses skeletal structure data from CT and motion capture data from an infrared position sensor. A 3-D model reconstructed from CT data is combined with the motion capture data. Using this system, we analyzed hip motion when getting up from and sitting down in a chair or picking up an object while sitting in a chair in 17 patients (26 hips) who underwent THA. To assess the accuracy of this system's measurements, open MRI was used to evaluate positions of skin markers against bones in five healthy volunteers in various postures. No impingement between bones and/or implants was found in any subjects during any activities. However, mean angle at the point of maximum hip flexion was different for each patient. The open MRI results indicated that average error in hip angle of the present system was within 5 degrees for each static posture. The functional position of the pelvis during daily activities must be taken into account when assessing the real risk of dislocation. The present system enables dynamic analysis involving not only alignment of components and bones of each patient, but also individual differences in characteristics of daily motions. Further investigation using this system can help determine safe ranges of motion for preventing hip dislocation, improving the accuracy of individualized guidance for patients regarding postoperative activities.

Для цитирования: Hagio Keisuke, Sugano Nobuhiko, Nishii Takashi, Miki Hidenobu, Otake Yoshito, Hattori Asaki, Suzuki Naoki, Yonenobu Kazuo, Yoshikawa Hideki, Ochi Takahiro. A novel system of four-dimensional motion analysis after total hip arthroplasty.. Journal of orthopaedic research : official publication of the Orthopaedic Research Society. 2004. DOI: 10.1016/j.orthres.2003.10.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.