MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1001/archopht.120.10.1348

Медицинская библиотека · Archives of ophthalmology (Chicago, Ill. : 1960) · 2002

Free radicals in phacoemulsification and aspiration procedures.

Takahashi Hiroshi, Sakamoto Atsuhiro, Takahashi Ryoki, Ohmura Takeo, Shimmura Shigeto, Ohara Kunitoshi

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To detect free radicals in phacoemulsification and aspiration procedures using electron-spin resonance and to observe the effect of ophthalmic viscosurgical devices (viscoelastic agents) on free radical intensity.

METHODS

(1) A test tube containing BSS Plus (Alcon Laboratories, Inc, Fort Worth, Tex) with 1% of the spin-trapping agent, 5,5'-dimethyl-1-pyrroline N-oxide, without irrigation and aspiration, was exposed to ultrasound (100% for 20 seconds). A preparation of hyaluronate sodium (Healon [a cohesive agent that contains 1% hyaluronate sodium] (Pharmacia, Uppsala, Sweden) or Viscoat [a dispersive agent that contains 3% hyaluronate sodium and 4% chondroitin sulfate] (Alcon Laboratories, Inc)) was added to the solution to observe inhibitory effects. (2) To simulate a clinical procedure, an eye model with irrigation and aspiration of a combination of 1% 5,5'-dimethyl-1-pyrroline N-oxide and BSS Plus, 25 mL/min, as the irrigating solution was exposed to ultrasound (for 10, 20, or 30 seconds). Healon or Viscoat was injected into the anterior chamber. Free radicals were measured by an electron-spin resonance spectrometer.

RESULTS

(1) A characteristic signal corresponding to hydroxyl radicals was detected. Similar inhibition by Healon and Viscoat was observed. (2) Two ophthalmic viscosurgical devices similarly suppressed the signal at 10 seconds. The inhibition by Healon ceased at 20 seconds, whereas Viscoat suppressed the signal throughout the time course.

CONCLUSIONS

Phacoemulsification produces hydroxyl radicals in the anterior chamber even with irrigation and aspiration. The effect of ophthalmic viscosurgical devices on free radicals depends on the retention of the materials within the anterior chamber.

CLINICAL RELEVANCE: There are complications associated with phacoemulsification.

Для цитирования: Takahashi Hiroshi, Sakamoto Atsuhiro, Takahashi Ryoki, Ohmura Takeo, Shimmura Shigeto, Ohara Kunitoshi. Free radicals in phacoemulsification and aspiration procedures.. Archives of ophthalmology (Chicago, Ill. : 1960). 2002. DOI: 10.1001/archopht.120.10.1348.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.