OBJECTIVE

Mechanical circulatory support (MCS) may be used for severe graft failure after heart transplantation, but the degree to which it is lifesaving is uncertain.

METHODS

Between June 1990 and December 2009, 53 patients after 1417 heart transplants (3.7%) required post-transplant MCS for acute rejection (n=17), biventricular failure (n=16), right ventricular failure (n=16), left ventricular failure (n=1), or respiratory failure (n=3). Although support was occasionally instituted remotely post-transplant (5>1 year), in 39 (73%) instances it was required within 1 week. Initial mode of support was extracorporeal membrane oxygenation in 43 patients (81%), biventricular assist device in 4 (7.5%), and right ventricular assist device in 6 (11%).

RESULTS

Risk of requiring respiratory support was highest in those with restrictive cardiomyopathy as indication for transplant, women, and those with elevated pulmonary pressure or renal failure. Complications of support, which increased progressively with its duration, included stroke in two patients (3.8%), infection in two (3.8%), and reoperation for bleeding (seven instances) in four (7.0%). Nineteen patients (36%) recovered and were removed from support, five (9.4%) underwent retransplantation (four after biventricular failure and one after acute rejection), and 29 died while on support (55%). Overall survival after initiating support was 94%, 83%, 66%, and 43% at 1, 3, 7, and 30 days, respectively. Patients requiring support for biventricular failure had better survival than those having acute rejection or other indications (P=0.03). Survival after retransplantation or removal from support following recovery was 88% at 1 year and 61% at 10 years.

CONCLUSION

Severe refractory heart failure after transplantation is a rare catastrophic event for which MCS offers the possibility of recovery or bridge to retransplantation, particularly for patients with biventricular failure in the absence of rejection. Early retransplantation should be considered in patients who show no evidence of graft recovery on MCS.

Для цитирования: Mihaljevic Tomislav, Jarrett Craig M, Gonzalez-Stawinski Gonzalo, Smedira Nicholas G, Nowicki Edward R, Thuita Lucy, Mountis Maria, Blackstone Eugene H. Mechanical circulatory support after heart transplantation.. European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery. 2012. DOI: 10.1016/j.ejcts.2011.04.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.