Role of low-dose cardiac CT scans in young children: a systematic review.
Систематический обзорСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Visakh T, Priya P S, Panakkal Nitika C, Sharath S, Suresh Sukumar, Prakashini Koteshwar
Аннотация
PURPOSE: To perform a systematic review of the diagnostic accuracy of low-dose cardiac CT scans in young children.
METHODS: A search of MEDLINE via the PubMed, Web of Science Core Collection, Cochrane Library, and ScienceDirect databases for English-language literature was performed to identify studies on low-dose cardiac CT for the diagnosis of congenital heart disease. The image quality, diagnostic value and effective radiation dose of low-dose cardiac CT scans were compared.
RESULTS: Fourteen studies utilized a total sample size of 474 neonates, infants, and young children. Twelve studies reported diagnostic accuracies ranging between 95.60% and 100.00%. Among the individual studies, the sensitivity ranged between 91.00% and 96.70%, whereas the specificity ranged between 92.30% and 99.91%. The effective radiation dose between individual studies ranged between 0.07mSv and 1.81mSv. The subjective image quality was either rated on a 5-point or a 4-point scale. Among the studies that used the 5-point scale, the image quality ranged between 3.77 and 4.90, whereas among the studies that used the 4-point scale, the image quality ranged between 1.20 and 3.06.
CONCLUSIONS: The findings of this study indicate that advanced CT scan protocols, such as high-pitched, dual-source, and ECG-triggered methods, can produce high-quality images and achieve very high diagnostic accuracy at extremely low radiation doses.
METHODS: A search of MEDLINE via the PubMed, Web of Science Core Collection, Cochrane Library, and ScienceDirect databases for English-language literature was performed to identify studies on low-dose cardiac CT for the diagnosis of congenital heart disease. The image quality, diagnostic value and effective radiation dose of low-dose cardiac CT scans were compared.
RESULTS: Fourteen studies utilized a total sample size of 474 neonates, infants, and young children. Twelve studies reported diagnostic accuracies ranging between 95.60% and 100.00%. Among the individual studies, the sensitivity ranged between 91.00% and 96.70%, whereas the specificity ranged between 92.30% and 99.91%. The effective radiation dose between individual studies ranged between 0.07mSv and 1.81mSv. The subjective image quality was either rated on a 5-point or a 4-point scale. Among the studies that used the 5-point scale, the image quality ranged between 3.77 and 4.90, whereas among the studies that used the 4-point scale, the image quality ranged between 1.20 and 3.06.