MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ejhf.3119

Медицинская библиотека · European journal of heart failure · 2024

Exercise catheterization in adults post-Fontan with normal and abnormal haemodynamic criteria: Insights into normal Fontan physiology.

Miranda William R, Jain C Charles, Borlaug Barry A, Connolly Heidi M, Burchill Luke J, Van De Bruaene Alexander, Egbe Alexander C

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

AIM: The normal (i.e. expected) haemodynamics in adults post-Fontan remain poorly delineated. Moreover, the definitions of elevated exercise pulmonary artery (PA) and PA wedge pressure (PAWP) for this population have not been described.

METHODS AND

RESULTS

Seventy-two adults post-Fontan undergoing exercise catheterization were categorized into abnormal (Group I, n = 59; defined as resting mean PA ≥14 mmHg and/or PAWP ≥12 mmHg, ΔPAWP/Δsystemic flow [Qs] >2 mmHg/L/min, and/or ΔPA/Δpulmonary flow >3 mmHg/L/min) and normal (Group II, n = 13) haemodynamics. Thirty-nine patients with non-cardiac dyspnoea (NCD) were included as controls. There was no difference in exercise arterial oxygen saturation (87% [81-92] vs. 89% [85-93], p = 0.29), while exercise PA pressure (27 [23-31] vs. 16 [14.5-19.5] mmHg, p < 0.001) and PAWP were higher (21 [18-28] vs. 12 [8-14] mmHg, p < 0.001) in Group I. At peak exercise, Group I had lower heart rate (97 [81-120] vs. 133 [112.5-147.5] bpm, p < 0.001) and Qs response (67.3 [43.8-93.1] vs. 105.9 (82-118.5) % predicted, p < 0.001) than Group II. Exercise superior vena cava pressures were higher (16 [14-22.5] vs. 5.5 [3-7.3] mmHg, p < 0.001) and arterial oxygen saturation lower (89% [85-93] vs. 97% [96-98], p < 0.001) in Group II compared to NCD, while no differences in PAWP, stroke volume index, heart rate, or Qs response were seen. If defined as two standard deviations above mean values for Group II, elevated PAWP and mean PA pressure post-Fontan would correspond to 20.6 mmHg and 25.8 mmHg, respectively.

CONCLUSION

PAWP >20 mmHg and mean PA pressure >25 mmHg could be used to define elevated values during exercise in adults post-Fontan. The major discrepancy in exercise haemodynamics among Group II compared to controls appears to be the degree of systemic venous hypertension and arterial desaturation.

Для цитирования: Miranda William R, Jain C Charles, Borlaug Barry A, Connolly Heidi M, Burchill Luke J, Van De Bruaene Alexander, Egbe Alexander C. Exercise catheterization in adults post-Fontan with normal and abnormal haemodynamic criteria: Insights into normal Fontan physiology.. European journal of heart failure. 2024. DOI: 10.1002/ejhf.3119.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.