The Annals of thoracic surgery · 2024
Modified-Bentall Single-Patch Konno Enlargement Technique for Aortic Stenosis and Prosthesis-Patient Mismatch.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Roselli Eric E, Kramer Benjamin P, Thompson Matthew A, Ngauv Julie, Snyder Abigail M, Hargrave Jennifer, Rodriguez Leonardo, Elgharably Haytham, McCurry Kenneth, Tong Michael Z, Vargo Patrick R, Blackstone Eugene H
Аннотация
BACKGROUND: Aortic stenosis and prosthesis-patient mismatch complicate surgery for patients with small left ventricular outflow tracts. We present outcomes of a modified-Bentall single-patch Konno enlargement (BeSPoKE) technique for complex left ventricular outflow tract obstruction in adults.
METHODS: The BeSPoKE technique facilitates a true outflow tract enlargement through an anterior septoventriculoplasty, using a single pericardial patch, followed by composite aortic valve-graft root replacement. Postoperative outflow tract geometry and valvular physiology were compared against preoperative measurements using echocardiography and computed tomographic angiography. Clinical outcomes at 2 years were assessed.
RESULTS: From October 2017 to March 2022, 25 adults (median age, 60 years; 84% women) underwent a BeSPoKE repair. Mean preoperative aortic valve gradient was 44 ± 19 mm Hg. Twenty-one patients (84%) had previous aortic valve replacements with prosthesis-patient mismatch; median implant size preoperatively was 19 mm. Postoperatively, all patients received a prosthesis of at least 21 mm, with a median upsizing of 2 (15th-85th percentile, 2-3 sizes). Mean postoperative aortic valve gradient was 8.5 ± 4.1 mm Hg (P < .001). The mean 2-year gradient was 8.3 ± 1.3 mm Hg. All patients with bioprosthetic replacements qualified for future transcatheter valve replacements. Postoperative complications included atrial fibrillation in 9 (36%) and complete heart block requiring pacemaker placement in 8 (32%). There were no operative deaths, and no reoperations were reported. There were 2 late noncardiac-related deaths; 2-year survival was 92%.
CONCLUSIONS: The BeSPoKE technique facilitates larger prosthesis placement, improves hemodynamics, and enables future transcatheter reinterventions. This approach is a safe treatment for complex left ventricular outflow tract obstruction and prosthesis-patient mismatch in adults.
METHODS: The BeSPoKE technique facilitates a true outflow tract enlargement through an anterior septoventriculoplasty, using a single pericardial patch, followed by composite aortic valve-graft root replacement. Postoperative outflow tract geometry and valvular physiology were compared against preoperative measurements using echocardiography and computed tomographic angiography. Clinical outcomes at 2 years were assessed.
RESULTS: From October 2017 to March 2022, 25 adults (median age, 60 years; 84% women) underwent a BeSPoKE repair. Mean preoperative aortic valve gradient was 44 ± 19 mm Hg. Twenty-one patients (84%) had previous aortic valve replacements with prosthesis-patient mismatch; median implant size preoperatively was 19 mm. Postoperatively, all patients received a prosthesis of at least 21 mm, with a median upsizing of 2 (15th-85th percentile, 2-3 sizes). Mean postoperative aortic valve gradient was 8.5 ± 4.1 mm Hg (P < .001). The mean 2-year gradient was 8.3 ± 1.3 mm Hg. All patients with bioprosthetic replacements qualified for future transcatheter valve replacements. Postoperative complications included atrial fibrillation in 9 (36%) and complete heart block requiring pacemaker placement in 8 (32%). There were no operative deaths, and no reoperations were reported. There were 2 late noncardiac-related deaths; 2-year survival was 92%.
CONCLUSIONS: The BeSPoKE technique facilitates larger prosthesis placement, improves hemodynamics, and enables future transcatheter reinterventions. This approach is a safe treatment for complex left ventricular outflow tract obstruction and prosthesis-patient mismatch in adults.