MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s1074-3804(05)80159-8

Медицинская библиотека · The Journal of the American Association of Gynecologic Laparoscopists · 1996

Metroplasty for the complete septate uterus: does cervical sparing matter?

Vercellini P, De Giorgi O, Cortesi I, Aimi G, Mazza P, Crosignani P G

СтатьяПеревод в очереди

Аннотация

STUDY

OBJECTIVES

To verify if section of the cervical septum facilitates hysteroscopic metroplasty of a complete septate uterus, and to determine if this technique is associated with intraoperative bleeding or postoperative obstetric complications.

DESIGN

Prospective, observational study.

SETTING

Academic department and tertiary care referral center for malformations of the female genital tract.

PATIENTS: Ten women with complete septate uterus.

INTERVENTIONS: The cervical portion of the septum was incised with Metzenbaum scissors and the corporeal portion with microscissors under hysteroscopic guidance.

MEASUREMENTS AND MAIN

RESULTS

Mean +/- SD operating time for the entire procedure was 24 +/- 7 minutes, with a mean distention fluid deficit of 480 +/- 190 ml. No significant bleeding was encountered during cervical septum incision. At follow-up hysteroscopy, the cervices were competent, and no women experienced second-trimester abortion or premature delivery.

CONCLUSIONS

Section of the cervical septum with scissors is simple, rapid, and safe, facilitates corporeal hysteroscopic metroplasty, and may be considered a valid procedure to correct a completely septate uterus.

Для цитирования: Vercellini P, De Giorgi O, Cortesi I, Aimi G, Mazza P, Crosignani P G. Metroplasty for the complete septate uterus: does cervical sparing matter?. The Journal of the American Association of Gynecologic Laparoscopists. 1996. DOI: 10.1016/s1074-3804(05)80159-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.