MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1155/2018/4069530

Медицинская библиотека · Evidence-based complementary and alternative medicine : eCAM · 2018

Difference between Right and Left Facial Surface Electromyography in Healthy People.

Kim Bo-Hyun, Kim Kyeong Han, Kim Lak-Hyung, Kim Jong-Uk, Yook Tae-Han

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

The study was to see whether there were differences in values of facial surface electromyography in subjects of good heath by muscles, age, and sex.

METHODS

It draws ratio between lower value and higher value (R-LV/HV) and asymmetry index (AI), based on root mean square (RMS) from measurement of facial surface electromyography (sEMG) in 154 people of healthy people (male:female = 70:84) aging between more than 20 and less than 70.

RESULTS

For R-LV/HV, it averages 81.70±14.60% on frontalis muscle, 73.74±19.12% on zygomaticus muscle, and 79.72±14.77% on orbicularis oris muscle. With analysis of the AI average was 10.87±10.14% on frontalis muscle, 16.71±14.79% on zygomaticus muscle, and 12.10±10.05% on orbicularis oris muscle. Both values were statistically significant in three parts of muscles as shown. Both of R-LV/HV and AI show no statistically significant difference on age and sex (p>0.05).

CONCLUSIONS

It could provide basic data for the future diagnosis of facial nerve palsy patients by measuring facial sEMG values for healthy people.

Для цитирования: Kim Bo-Hyun, Kim Kyeong Han, Kim Lak-Hyung, Kim Jong-Uk, Yook Tae-Han. Difference between Right and Left Facial Surface Electromyography in Healthy People.. Evidence-based complementary and alternative medicine : eCAM. 2018. DOI: 10.1155/2018/4069530.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.