Difficult Blood Typing Caused by Rouleaux Agglutination in Patient with Acute Brain Trauma: a Case Report.
Клинический случайСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Liang Ying, Su Feng-Xue, Zhou Xu-Wei, Wu Shi-Min
Аннотация
BACKGROUND: Rouleaux agglutination is a common cause of difficult blood typing, but it is rarely reported in patients with acute brain trauma.
METHODS: This article describes a 69-year-old male with head injury who was admitted to the hospital. Blood typing showed type O, Rh(D) positive, but the Rh(D) control was also positive. After ruling out the possibility of the patient having abnormal autoantibodies, it was suspected that rouleaux agglutination might be the cause. Microscopic examination of the specimen revealed rouleaux agglutination, which was believed to be the cause of the false-positive Rh(D) control result. The patient's red blood cells were treated with physiological saline and retested by microcolumn gel card testing.
RESULTS: The retest showed negative Rh(D) control results, indicating normal results. The patient subsequently received normal blood transfusion.
CONCLUSIONS: Laboratory personnel should be aware of the possibility of difficult blood typing caused by rouleaux agglutination in various diseases, especially in relatively rare traumatic diseases.
METHODS: This article describes a 69-year-old male with head injury who was admitted to the hospital. Blood typing showed type O, Rh(D) positive, but the Rh(D) control was also positive. After ruling out the possibility of the patient having abnormal autoantibodies, it was suspected that rouleaux agglutination might be the cause. Microscopic examination of the specimen revealed rouleaux agglutination, which was believed to be the cause of the false-positive Rh(D) control result. The patient's red blood cells were treated with physiological saline and retested by microcolumn gel card testing.
RESULTS: The retest showed negative Rh(D) control results, indicating normal results. The patient subsequently received normal blood transfusion.
CONCLUSIONS: Laboratory personnel should be aware of the possibility of difficult blood typing caused by rouleaux agglutination in various diseases, especially in relatively rare traumatic diseases.