OBJECTIVE

Many studies have indicated that intra-abdominal pressure (IAP) is positively correlated with central venous pressure (CVP) in severe cases. However, although elevated IAP is common in patients with severe acute pancreatitis (SAP), its relationship with CVP remains unclear. Our study aimed to investigate the association of IAP with CVP in early-phase SAP patients.

METHODS

In total, 116 SAP patients were included in this retrospective study. On the first day of hospitalization, blood samples were collected for biochemical examination and cytokine concentration monitoring. Additionally, a urinary catheter and right subclavian vein catheter were inserted for IAP and CVP measurement, respectively. Other routine clinical data were also recorded.

RESULTS

Within 24 hours after hospitalization, CVP fluctuated and increased with increasing IAP up to 15.7 mmHg (P = 0.054) but decreased with increasing IAP when the IAP was > 15.7 mmHg (P < 0.001). After adjusting for abdominal perfusion pressure (APP) and mean arterial pressure (MAP), a similar distribution was observed. An inverted U-shaped trend between IAP and CVP was also present in the groups classified according to the patient's sex, local complications, ascites, and serum amylase levels.

CONCLUSIONS

CVP and IAP have an inverted U-shaped relationship, with a peak at an IAP of 15.7 mmHg in the early phase of SAP. After this peak, CVP decreases as IAP increases. These results have crucial implications for clinical fluid resuscitation in SAP patients. In particular, because one CVP value might be correlated with different IAP values in patients with the same CVP, the volume of fluid needed might be different.

Для цитирования: Yang Chong, Yang Zhiyong, Chen Xinglin, Liu Tao, Gou Shanmiao, Chen Changzhong, Xiao Jun, Jin Xin, He Zhiqiang, Dong Liming, Zhang Yushun, Luo Na, Wu Heshui, Wang Chunyou. Inverted U-Shaped Relationship between Central Venous Pressure and Intra-Abdominal Pressure in the Early Phase of Severe Acute Pancreatitis: A Retrospective Study.. PloS one. 2015. DOI: 10.1371/journal.pone.0128493.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.