m+Medelevator.RU
← Поиск публикаций
Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2015

Axillary vein puncture using fluoroscopic landmarks: a safe and effective approach for implantable cardioverter defibrillator leads.

Клиническое исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Migliore Federico, Siciliano Mariachiara, De Lazzari Manuel, Ferretto Sonia, Valle Chiara Dalla, Zorzi Alessandro, Corrado Domenico, Iliceto Sabino, Bertaglia Emanuele

Аннотация

PURPOSE: Axillary vein puncture is an effective method for pacemaker lead insertion with less complications compared with subclavian vein puncture; however, there are limited data on implantable cardioverter defibrillator (ICD) implantation with this technique. We reported our experience with a blind axillary vein puncture using fluoroscopic landmarks consisting of the outer edge of the first rib and the body surface of the second rib for ICD lead implantation.

METHODS: The study population included 103 consecutive patients (mean age 59 ± 9 years) referred for ICD implantation using axillary vein puncture without contrast venography. An 18-gauge needle was advanced toward the outer edge of the fist rib below the clavicle or the body surface of the second rib. If the vein was not entered, the needle was withdrawn and the puncture was repeated with slight variations of needle direction for a maximum of four times, then contrast-guided vein puncture was performed.

RESULTS: The total implanted leads were 152 including 103 right ventricular leads, 35 right atrial leads, and 14 left ventricular epicardial leads. Blind axillary vein puncture was successful obtained in 96 (93.2 %) patients. The rate of success was higher using the body surface of the second rib compared with the outer edge of the first rib (88.7 vs. 100 %; p = 0.04).Contrast venography was required in seven (6.8 %) patients because of vein course abnormality (n = 5) or vasospasm (n = 2). No acute complications or device-related complications were recorded during a mean follow-up of 12 ± 5 months.

CONCLUSIONS: Axillary vein access using fluoroscopic landmarks, especially the body surface of the second rib, is an effective approach for ICD implantation and offers the potential to avoid complications usually observed with traditional subclavian vein approach.