Diagnostic microbiology and infectious disease · 2022
Assessment of a fully automated RPR assay (Mediace RPR) for serological diagnosis and follow-up of syphilis: a retrospective study.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Leroy Anne-Gaëlle, Robert Manon, Carpentier Maxime, Bastidon Christophe, Gautreau Blandine, Lefebvre Maeva, Bonnet Bénédicte, Bernier Claire, Corvec Stéphane, Guillouzouic Aurélie
Аннотация
OBJECTIVES: This study assessed the Mediace RPR assay, an automated RPR (aRPR), for syphilis diagnosis and serological follow-up.
METHODS: Serums from patients positively screened for syphilis between January 2017 and December 2019 were retrospectively selected. A focus was performed on patients with a serological follow-up after treatment and/or a reinfection. Serums were tested by both manual (mRPR) and aRPR tests. Categorical and Quantitative Agreements (CA and QA), and serological follow-up conclusions were analyzed.
RESULTS: 236 serums from 85 patients (99% of male, 66% of HIV-infected) were included. The overall QA was 54.2%. CA was low (79.7%) especially for samples with low RPR titers. No prozone effect was observed. Serological follow-up after treatment led to similar conclusions, although aRPR titers often decreased faster. Over 26 episodes of reinfection, 4 (15.4%) were misdiagnosed with the aRPR.
CONCLUSIONS: While the Mediace aRPR presents the advantages of an automated test, its poor sensitivity in low titers may limit its use.
METHODS: Serums from patients positively screened for syphilis between January 2017 and December 2019 were retrospectively selected. A focus was performed on patients with a serological follow-up after treatment and/or a reinfection. Serums were tested by both manual (mRPR) and aRPR tests. Categorical and Quantitative Agreements (CA and QA), and serological follow-up conclusions were analyzed.
RESULTS: 236 serums from 85 patients (99% of male, 66% of HIV-infected) were included. The overall QA was 54.2%. CA was low (79.7%) especially for samples with low RPR titers. No prozone effect was observed. Serological follow-up after treatment led to similar conclusions, although aRPR titers often decreased faster. Over 26 episodes of reinfection, 4 (15.4%) were misdiagnosed with the aRPR.