Journal of the American Veterinary Medical Association · 2022
Stabilization of a vertebral fracture by a monolateral external fixator placed percutaneously with fluoroscopy guidance in a rabbit (Oryctolagus cuniculus).
Клинический случайСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Rosas-Navarro José, Paoletti Carlo, Quinton Jean-François, Rossetti Diego
Аннотация
CASE DESCRIPTION: A 2-year-old intact male Mini Lop rabbit (Oryctolagus cuniculus) exhibited acute paraplegia and was suspected of having a traumatic spinal injury after leaping from the owner's arms.
CLINICAL FINDINGS: In the physical examination, the patient was conscious and responsive and presented a loss of hind-limb motor function. The results of the neurologic examination indicated a T3-L3 spinal cord lesion. Vertebral column radiography and CT showed a fracture of the dorsal arch in the right caudal part of vertebra L1 and a fracture of the caudal end plate of vertebra L1 without displacement.
TREATMENT AND OUTCOME: The vertebral fracture was stabilized by a monolateral external fixator placed percutaneously with fluoroscopy guidance. The rabbit was discharged 48 hours after surgery. Three days later, the rabbit was able to walk with mild paraparesis, and 2 weeks after surgery, the rabbit showed full recovery of neurologic function. The follow-up performed 6 weeks after surgery showed normal gait, good alignment and complete consolidation of the fracture. The external fixator was then removed. The follow-up examination and radiographic findings showed complete recovery at 2 and 6 months after surgery.
CLINICAL RELEVANCE: The most common cause of traumatic posterior paralysis in rabbits is vertebral fracture. This article describes the possibility and successful outcome of stabilizing a vertebral fracture in a rabbit with an external fixator using a minimally invasive fluoroscopic technique. This technique, described to the authors' knowledge for the first time in a rabbit, allows a fracture to be stabilized accurately without any incisions while minimizing complications and postoperative pain.
CLINICAL FINDINGS: In the physical examination, the patient was conscious and responsive and presented a loss of hind-limb motor function. The results of the neurologic examination indicated a T3-L3 spinal cord lesion. Vertebral column radiography and CT showed a fracture of the dorsal arch in the right caudal part of vertebra L1 and a fracture of the caudal end plate of vertebra L1 without displacement.
TREATMENT AND OUTCOME: The vertebral fracture was stabilized by a monolateral external fixator placed percutaneously with fluoroscopy guidance. The rabbit was discharged 48 hours after surgery. Three days later, the rabbit was able to walk with mild paraparesis, and 2 weeks after surgery, the rabbit showed full recovery of neurologic function. The follow-up performed 6 weeks after surgery showed normal gait, good alignment and complete consolidation of the fracture. The external fixator was then removed. The follow-up examination and radiographic findings showed complete recovery at 2 and 6 months after surgery.
CLINICAL RELEVANCE: The most common cause of traumatic posterior paralysis in rabbits is vertebral fracture. This article describes the possibility and successful outcome of stabilizing a vertebral fracture in a rabbit with an external fixator using a minimally invasive fluoroscopic technique. This technique, described to the authors' knowledge for the first time in a rabbit, allows a fracture to be stabilized accurately without any incisions while minimizing complications and postoperative pain.