MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12893-022-01475-5

Медицинская библиотека · BMC surgery · 2022

Recurrent graft failure secondary to portal vein steal syndrome: a case report with an unusual indication for a third liver transplant.

Tropea Alessandro, Barbàra Marco, Pagano Duilio, Marrone Gianluca, Petridis Ioannis, Li Petri Sergio, Cintorino Davide, Gruttadauria Salvatore

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Portal vein shunt is common in chronic hepatic diseases and after a liver transplant. Ensuring a satisfactory portal flow is essential to support a rapid liver recovery, of paramount importance to meet the recipient's metabolic needs.

CASE PRESENTATION: We report the case of a 32-year-old female undergoing a third liver transplant due to recurrence of graft failure secondary to portosystemic shunting. The patient, affected with biliary atresia, was first transplanted in 2009 with a right split liver graft. The clinical course was complicated by biliary stenosis of the Roux-en-Y anastomosis and multiple episodes of acute rejection treated with steroid boluses, plastic dilation of the biliary anastomosis, and biliary catheter placement. Unfortunately, in 2017 a liver biopsy showed an autoimmunity with histological evidence of ANA 1:80 (granular and nucleolar pattern). This was a contributing factor of liver function impairment, leading to the need to perform a second liver transplant, complicated by an acute rejection, with only a partial response to steroid therapy. Due to the further worsening of the liver function (MELD: 40, Child-Pugh: C11), the patient was relisted for a liver transplant. After five days, she received her third liver transplant, with an entire graft of an AB0 identical group. Intraoperative exploration revealed multiple collaterals and large splenocaval shunts, with a significant alteration of the portal flow and hypertension, isolated and closed with a vascular stapler to restore the graft's regular portal vein flow.

CONCLUSIONS

In patients listed for a liver transplant, portal steal syndrome should be identified prior to the transplant. Our recommendation is to consider intraoperative or perioperative closure of the portal collateral varices.

Для цитирования: Tropea Alessandro, Barbàra Marco, Pagano Duilio, Marrone Gianluca, Petridis Ioannis, Li Petri Sergio, Cintorino Davide, Gruttadauria Salvatore. Recurrent graft failure secondary to portal vein steal syndrome: a case report with an unusual indication for a third liver transplant.. BMC surgery. 2022. DOI: 10.1186/s12893-022-01475-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.