European heart journal. Case reports · 2022

A case of cardiac strangulation following epicardial pacemaker implantation in an adult: a case report.

Клинический случайСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kang Ryeonshi, Tanaka Toshikazu D, Yoshitake Michio, Yoshimura Michihiro

Аннотация

BACKGROUND: Cardiac strangulation (CS) is a rare but potentially devastating complication caused by the leads of an epicardial pacemaker (EP). Most cases have been reported in paediatric patients, and there has been no report wherein the diagnosis was made in a living, adult patient, and treated successfully.

CASE SUMMARY: A 31-year-old woman with a history of atrial septal defect (ASD) patch closure and EP implantation for congenital atrial stand-still presented with dyspnoea on exertion. The blood investigation of the patient showed liver dysfunction, chest radiography showed pulmonary artery dilatation, and transthoracic echocardiography showed right chambers dysfunction. Right heart catheterization showed haemodynamics similar to those of constrictive pericarditis, eventually leading to the diagnosis of CS due to EP leads. The patient was successfully operated upon.

DISCUSSION: We reported the first case where CS was diagnosed in adulthood and successfully treated with surgical intervention. Cardiac strangulation is challenging to diagnose because of the small number of cases reported and the lack of definitive diagnostic algorithms or criteria. Surgical EP lead removal should be performed without hesitation in cases where CS is considered the primary aetiology of critical symptoms or complications because surgical removal is the only fundamental treatment for CS. In addition, paediatric patients undergoing EP implantation need for close follow-up.