MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fcimb.2022.816238

Медицинская библиотека · Frontiers in cellular and infection microbiology · 2022

Rapid Visual Detection of Hepatitis C Virus Using Reverse Transcription Recombinase-Aided Amplification-Lateral Flow Dipstick.

Wang Haili, Zhang Yuhang, Zhou Jingming, Li Ming, Chen Yumei, Liu Yankai, Liu Hongliang, Ding Peiyang, Liang Chao, Zhu Xifang, Zhang Ying, Xin Cheng, Zhang Gaiping, Wang Aiping

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Hepatitis C virus (HCV) infection is a global public health threat. Reaching the World Health Organization's objective for eliminating viral hepatitis by 2030 will require a precise disease diagnosis. While immunoassays and qPCR play a significant role in detecting HCV, rapid and accurate point-of-care testing is important for pathogen identification. This study establishes a reverse transcription recombinase-aided amplification-lateral flow dipstick (RT-RAA-LFD) assay to detect HCV. The intact workflow was completed within 30 min, and the detection limit for synthesized C/E1 plasmid gene-containing plasmid was 10 copies/μl. In addition, the test showed good specificity, with no cross-reactivity observed for hepatitis A virus, hepatitis B virus, HIV, syphilis, and human papillomavirus virus. Using extracted RNAs from 46 anti-HCV antibody-positive samples, RT-RAA-LFD showed 100% positive and negative concordance rates with qPCR. In summary, the RT-RAA-LFD assay established in this study is suitable for the rapid clinical detection of HCV at the community level and in remote areas.

Для цитирования: Wang Haili, Zhang Yuhang, Zhou Jingming, Li Ming, Chen Yumei, Liu Yankai, Liu Hongliang, Ding Peiyang, Liang Chao, Zhu Xifang, Zhang Ying, Xin Cheng, Zhang Gaiping, Wang Aiping. Rapid Visual Detection of Hepatitis C Virus Using Reverse Transcription Recombinase-Aided Amplification-Lateral Flow Dipstick.. Frontiers in cellular and infection microbiology. 2022. DOI: 10.3389/fcimb.2022.816238.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.