BACKGROUND

The risk of radiation exposure in the surgical operating room (OR) and/or catheterization laboratory is now well established. Complex endovascular procedures often require multiple approaches and different positioning of the staff members around the patient, potentially increasing the levels of radiations exposure. Our goal was to evaluate the levels of radiation exposure of the members of the staff during endovascular aortic procedures in order to propose radioprotection optimization.

METHODS

We included 41 aortic endovascular procedures out of 114 procedures performed between January 12, 2014, and August 31, 2015, including 24 standard endovascular aortic aneurysm repair (EVAR), 7 EVAR with iliac branch (EVARib), 8 complex fenestrated/branched EVAR (F/B EVAR), and 2 thoracic EVAR (TEVAR). Procedures were performed in an OR equipped with a carbon fiber table and a mobile fluoroscopy C-arm. We collected the usual dosimetry data given by the C-arm as well as the patient's peak skin dose (PSD). In all staff members, radiation exposure was measured with thermoluminescent chip dosimeters placed on both temples, on posterior sides of both hands, and on both lower legs.

RESULTS

PSD levels were low for EVAR because 24 patients had values below the reading threshold. PSD significantly increased with more complex procedures. Main operator (MO) received the higher level of irradiation on whole body, hands, and ankles. Eye lenses irradiation was higher on both assistant operators (AOs). Other members received low levels of irradiation. We found a high ranges of radiation exposure with a high risk of exposure for the AO, mainly for F/B EVAR and EVARib.

CONCLUSIONS

Even if all personal protections are used, staff positioning is a major point that must be considered. If MO is supposed to be the most exposed to X-rays, specific conditions of positioning of the AO may be at risk of exposure.

Для цитирования: Clauss Nicolas, Kuntz Salomé, Colvard Benjamin, Ohana Mickael, Mertz Luc, Lejay Anne, Chakfe Nabil. Intraoperative Staff Radiation Exposure During Aortic Endovascular Procedures.. Annals of vascular surgery. 2024. DOI: 10.1016/j.avsg.2024.01.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.