MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jbiomech.2012.10.038

Медицинская библиотека · Journal of biomechanics · 2012

Patient-specific bicuspid valve dynamics: overview of methods and challenges.

Chandran Krishnan B, Vigmostad Sarah C

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАОбзорПеревод в очереди

Аннотация

About 1-2 % of the babies are born with bicuspid aortic valves instead of the normal aortic valve with three leaflets. A significant portion of the patients with the congenital bicuspid valve morphology suffer from aortic valve stenosis and/or ascending aortic dilatation and dissection thus requiring surgical intervention when they are young adults. Patients with bicuspid aortic valves (BAVs) have also been found to develop valvular stenosis earlier than those with the normal aortic valve. This paper overviews current knowledge of BAVs, where several studies have suggested that the mechanical stresses induced on the valve leaflets and the abnormal flow development in the ascending aorta may be an important factor in the diseases of the valve and the aortic root. The long-term goals of the studies being performed in our laboratory are aimed towards potential stratification of bicuspid valve patients who may be at risk for developing these pathologies based on analyzing the hemodynamic environment of these valves using fluid-structure interaction (FSI) modeling. Patient-specific geometry of the normal tri-cuspid and bicuspid valves are reconstructed from real-time 3D ultrasound images and the dynamic analyses performed in order to determine the potential effects of mechanical stresses on the valve leaflet and aortic root pathology. This paper describes the details of the computational tools and discusses challenges with patient-specific modeling.

Для цитирования: Chandran Krishnan B, Vigmostad Sarah C. Patient-specific bicuspid valve dynamics: overview of methods and challenges.. Journal of biomechanics. 2012. DOI: 10.1016/j.jbiomech.2012.10.038.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.