IEEE transactions on bio-medical engineering · 2026

Fusing Tabular Features and Deep Learning for Fetal Heart Rate Analysis: A Clinically Interpretable Model for Fetal Compromise Detection.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Mendis Lochana, Karmakar Debjyoti, Palaniswami Marimuthu, Brownfoot Fiona, Keenan Emerson

Аннотация

OBJECTIVE: Cardiotocography (CTG) is commonly used to monitor fetal heart rate (FHR) and assess fetal well-being during labor. However, its effectiveness in reducing adverse outcomes remains limited due to low sensitivity and high false-positive rates. This study aims to develop an interpretable deep learning model that fuses FHR time series with tabular clinical features to improve prediction of fetal compromise (umbilical artery pH $< $ 7.05).

METHODS: We introduce Fusion ResNet, a novel architecture combining residual convolutional networks for FHR signal processing with a parallel neural network for tabular features. The model was trained and internally validated on a private dataset of 9,887 FHR recordings. External validation was performed on the open-access CTU-UHB dataset comprising 552 recordings. Model interpretability was evaluated using Shapley Additive Explanations (SHAP) and Gradient-Weighted Class Activation Mapping (Grad-CAM).

RESULTS: Fusion ResNet achieved a mean area under the ROC curve (AUC) of 0.77 during internal cross-validation and a state-of-the-art AUC of 0.84 on the CTU-UHB dataset, outperforming existing deep learning approaches. SHAP analysis identified key clinical features contributing to predictions, while Grad-CAM highlighted salient FHR patterns linked to fetal compromise.

CONCLUSION: The proposed model enhances predictive accuracy while providing clinically meaningful explanations, enabling more transparent and reliable CTG interpretation.

SIGNIFICANCE: This work demonstrates the potential of interpretable deep learning to improve fetal monitoring by integrating multimodal data, supporting timely and informed decision-making in obstetric care.