Cerebral embolic protection during transcatheter stent expansion of restrictive extra-cardiac Fontan conduit.

Haddad Raymond N, Naggara Olivier, Bonnet Damien, Malekzadeh-Milani Sophie

Клинический случайСтатьяПеревод в очереди

Аннотация

We report a 20-year-old female patient (76 Kg/164 cm) with an extra-cardiac Fontan circulation who was referred to our institution for exertional dyspnoea and desaturation. The patient was diagnosed with a large calcified thrombus at the level of the Fontan fenestration, protruding inside the lumen of the conduit and reducing the diameter by half with a 3 mmHg pressure gradient. Transcatheter stent expansion of the obstructed extra-cardiac conduit was done with a 48 mm long XXL PTFE-covered Optimus-CVS® under temporary cerebral embolic protection with a TriGUARD-3™ deflection filter device (Keystone Heart). There was no procedural complication and the 3 months clinical outcomes are good.

Для цитирования: Haddad Raymond N, Naggara Olivier, Bonnet Damien, Malekzadeh-Milani Sophie. Cerebral embolic protection during transcatheter stent expansion of restrictive extra-cardiac Fontan conduit.. Cardiology in the young. 2023. DOI: 10.1017/s1047951123004109.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.