MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/asia.201402923

Медицинская библиотека · Chemistry, an Asian journal · 2014

Unique fluorogenic ratiometric fluorescent chemodosimeter for rapid sensing of CN(-) in water.

Mahapatra Ajit Kumar, Maiti Kalipada, Manna Saikat Kumar, Maji Rajkishor, Mukhopadhyay Chitrangada Das, Pakhira Bholanath, Sarkar Sabyasachi

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A new benzimidazole-spiropyran conjugate chemosensor molecule (BISP) has been synthesized and characterized by (1)H NMR spectroscopy, mass spectrometry (ESI-MS), and elemental analysis. The two isomeric forms (BISP↔BIMC) were shown to be highly selective and sensitive to CN(-) among the ten anions studied in aqueous HEPES buffer, as shown by fluorescence and absorption spectroscopy and even by visual color changes, with a detection limit of 1.7 μM for BIMC. The reaction of CN(-) with BIMC was monitored by (1)H NMR spectroscopy, high-resolution mass spectrometry (HRMS), UV/Vis measurements, and fluorescence spectroscopy in HEPES buffer of pH 7.4. TDDFT calculations were performed in order to correlate the electronic properties of the chemosensor with its cyanide complex. Further, titration against thiophilic metal ions like Au(3+), Cu(2+), Ag(+), and Hg(2+) with [BIMC-CN] in situ showed that it acts as a secondary recognition ensemble toward Au(3+) and Cu(2+) by switch-on fluorescence. In addition, a reversible logic-gate property of BIMC has been demonstrated through a feedback loop in the presence of CN(-) and Au(3+) ions, respectively. Furthermore, the use of BIMC to detect CN(-) in live cells by fluorescence imaging has also been demonstrated. Notably, test strips based on BIMC were fabricated, which could serve as convenient and efficient CN(-) test kits.

Для цитирования: Mahapatra Ajit Kumar, Maiti Kalipada, Manna Saikat Kumar, Maji Rajkishor, Mukhopadhyay Chitrangada Das, Pakhira Bholanath, Sarkar Sabyasachi. Unique fluorogenic ratiometric fluorescent chemodosimeter for rapid sensing of CN(-) in water.. Chemistry, an Asian journal. 2014. DOI: 10.1002/asia.201402923.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.