m+Medelevator.RU
← Поиск публикаций
Heart (British Cardiac Society) · 2018

Ambulatory blood pressure and long-term risk for atrial fibrillation.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Tikhonoff Valérie, Kuznetsova Tatiana, Thijs Lutgarde, Cauwenberghs Nicholas, Stolarz-Skrzypek Katarzyna, Seidlerová Jitka, Malyutina Sofia, Gilis-Malinowska Natasza, Swierblewska Ewa, Kawecka-Jaszcz Kalina, Filipovský Jan, Narkiewicz Krzysztof, Lip Gregory Y H, Casiglia Edoardo, Staessen Jan A, European Project On Genes in Hypertension (EPOGH) Investigators

Аннотация

OBJECTIVE: Data on the contribution of ambulatory blood pressure (ABP) components to the risk of developing atrial fibrillation (AF) are limited. We prospectively tested the hypothesis that ABP may represent a potentially modifiable risk factor for the development of AF in a European population study.

METHODS: We recorded daytime blood pressure (BP) in 3956 subjects randomly recruited from the general population in five European countries. Of these participants, 2776 (70.2%) underwent complete 24-hour ABP monitoring. Median follow-up was 14 years. We defined daytime systolic BP load as the percentage BP readings above 135 mm Hg. The incidence of AF was assessed from ECGs obtained at baseline and follow-up and from records held by general practitioners and/or hospitals.

RESULTS: Overall, during 58 810 person-years of follow-up, 143 participants experienced new-onset AF. In adjusted Cox models, each SD increase in baseline 24 hours, daytime and night-time systolic BP was associated with a 27% (P=0.0056), 22% (P=0.023) and 20% (P=0.029) increase in the risk for incident AF, respectively. Conventional systolic BP was borderline associated with the risk of AF (18%; P=0.06). As compared with the average population risk, participants in the lower quartile of daytime systolic BP load (<3%) had a 51% (P=0.0038) lower hazard for incident AF, whereas in the upper quartile (>38%), the risk was 46% higher (P=0.0094).

CONCLUSIONS: Systolic ABP is a significant predictor of incident AF in a population-based cohort. We also observed that participants with a daytime systolic BP load >38% had significantly increased risk of incident AF.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты