Four-year results of the Bolton relay proximal scallop endograft in the management of thoracic and thoracoabdominal aortic pathology with unfavorable proximal landing zone.

СтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Hanna Lydia, Abdullah Ammar, Kashef Elika, Riga Celia, Jenkins Michael, Bicknell Colin, Gibbs Richard, Hamady Mohammad

Аннотация

BACKGROUND: Thoracic endovascular aortic repair with a scallop design (scallop-TEVAR) is a useful treatment strategy to extend the proximal landing zone (PLZ), while maintaining perfusion to one or more of the supra-aortic trunks (SATs) when treating aortic pathology with an unfavorable PLZ. The durability of this approach with the Bolton Relay scallop endograft (Terumo Aortic, Sunrise, Fla) has not been established.

METHODS: A retrospective review of prospectively collected data on consecutive patients that received scallop-TEVAR in zones 0 to 2 at a tertiary aortic unit was undertaken. The main outcome was durability, characterized by survival estimates, freedom from reintervention to the thoracic aorta and PLZ, migration and aneurysm sac regression.

RESULTS: Between 2009 and 2019, 38 patients (71% male; median age, 70 years) underwent scallop-TEVAR for thoracic aortic pathology (n = 28, 74%) or as a part of thoracoabdominal aneurysm repair (n = 10 [26%]). The use of scallop-TEVAR significantly extended the PLZ (median, 5 mm preoperative PLZ vs 26 mm extended PLZ; P = .0001). A total of 41 SATs were perfused with a scallop, including the left subclavian artery (n = 25), left common carotid artery (n = 6), neo/innominate artery (n = 4), left subclavian artery, and vertebral artery (n = 1), innominate artery, and left common carotid artery (n = 2) in conjunction with 15 extra-anatomical bypasses. The PLZ was at Ishimaru zone 0 and 1 in 6 cases (16%), respectively, and zone 2 in 26 cases (68%). Technical success was 98%. The 30-day mortality was 5% (2/38; 1 death from myocardial infarction and 1 from multiorgan failure). A minor stroke occurred in three patients (8%) and temporary spinal cord ischemia in two patients (5%). The median follow-up was 4.5 years (range, 0-10.53 years) during which two patients (5%) developed type Ia endoleak and required intervention to the PLZ (one from device-related migration and one from disease progression). All-cause and aorta-related survival were 72% and 85% and freedom from thoracic and PLZ reintervention was 92% and 97%, respectively. There were no cases of early or late thoracic aortic rupture, retrograde type A aortic dissection or SAT occlusion.

CONCLUSIONS: Scallop-TEVAR offers a less invasive treatment option to extend the seal zone in selected patients with an unfavorable PLZ, allowing for a durable repair in terms of overall survival and reintervention. Periprocedural stroke remains a principle concern.