MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/14767058.2017.1293022

Медицинская библиотека · The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians · 2017

Influence of difficulty of instrumentation with vacuum on the rate of levator ani muscle avulsion identified by 3-4 d transperineal ultrasound.

García Mejido José Antonio, De la Fuente Vaquero Paloma, Fernández Palacín Ana, Aquise Pino Adriana, Bonomi Barby María José, Sainz Bueno José Antonio

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

Evaluation of the influence of difficulty of instrumentation with vacuum on the rate of levator ani muscle (LAM) avulsions.

MATERIALS AND

METHODS

Prospective observational study with 86 nulliparous women with at term gestation who required instrumentation with vacuum to complete fetal extraction. After every delivery, each explorer reported the number of vacuum tractions needed to complete fetal extraction, as well as the subjective complexity of the instrumentation. LAM avulsion rate was assessed by 3D-4D transperineal ultrasound evaluation 6 months after delivery.

RESULTS

Seventy nine cases were evaluated and classified as either "easy" delivery (below three vacuum tractions; n = 49) or "difficult" delivery (three or more vacuum tractions; n = 30). No differences in obstetric characteristics were observed between study groups, with the following exceptions: fetal head circumference (34.8 ± 2.7 versus 35.2 ± 1.1; p = .013) and fetal weight at birth (3260 ± 421 versus 3500 ± 421; p = .016). No statistically significant differences between study groups were observed in LAM avulsion rate (36.7 versus 30%) and levator hiatus area (cm2) at rest (18.44 ± 3.95 versus 17.75 ± 3.90).

CONCLUSIONS

The number of vacuum tractions needed to complete fetal extraction is not associated to a higher LAM avulsion rate nor with differences in levator hiatus area.

Для цитирования: García Mejido José Antonio, De la Fuente Vaquero Paloma, Fernández Palacín Ana, Aquise Pino Adriana, Bonomi Barby María José, Sainz Bueno José Antonio. Influence of difficulty of instrumentation with vacuum on the rate of levator ani muscle avulsion identified by 3-4 d transperineal ultrasound.. The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians. 2017. DOI: 10.1080/14767058.2017.1293022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.