DOI 10.1080/14767058.2017.1293022
Influence of difficulty of instrumentation with vacuum on the rate of levator ani muscle avulsion identified by 3-4 d transperineal ultrasound.
Аннотация
OBJECTIVES
Evaluation of the influence of difficulty of instrumentation with vacuum on the rate of levator ani muscle (LAM) avulsions.
MATERIALS AND
METHODS
Prospective observational study with 86 nulliparous women with at term gestation who required instrumentation with vacuum to complete fetal extraction. After every delivery, each explorer reported the number of vacuum tractions needed to complete fetal extraction, as well as the subjective complexity of the instrumentation. LAM avulsion rate was assessed by 3D-4D transperineal ultrasound evaluation 6 months after delivery.
RESULTS
Seventy nine cases were evaluated and classified as either "easy" delivery (below three vacuum tractions; n = 49) or "difficult" delivery (three or more vacuum tractions; n = 30). No differences in obstetric characteristics were observed between study groups, with the following exceptions: fetal head circumference (34.8 ± 2.7 versus 35.2 ± 1.1; p = .013) and fetal weight at birth (3260 ± 421 versus 3500 ± 421; p = .016). No statistically significant differences between study groups were observed in LAM avulsion rate (36.7 versus 30%) and levator hiatus area (cm2) at rest (18.44 ± 3.95 versus 17.75 ± 3.90).
CONCLUSIONS
The number of vacuum tractions needed to complete fetal extraction is not associated to a higher LAM avulsion rate nor with differences in levator hiatus area.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.