DOI 10.1097/eja.0000000000000779

Медицинская библиотека · European journal of anaesthesiology · 2018

Comparison of double intravenous vasopressor automated system using nexfin versus manual vasopressor bolus administration for maintenance of haemodynamic stability during spinal anaesthesia for caesarean delivery: A randomised double-blind controlled trial.

Sng Ban Leong, Du Wei, Lee Man Xin, Ithnin Farida, Mathur Deepak, Leong Wan Ling, Sultana Rehena, Han Nian-Lin R, Sia Alex Tiong Heng

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Hypotension is a common side effect of spinal anaesthesia during caesarean delivery and is associated with maternal and foetal adverse effects. We developed an updated double intravenous vasopressor automated (DIVA) system that administers phenylephrine or ephedrine based on continuous noninvasive haemodynamic monitoring using the Nexfin device.

OBJECTIVE

The aim of our present study is to compare the performance and reliability of the DIVA system against Manual Vasopressor Bolus administration.

DESIGN

A randomised, double-blind controlled trial.

SETTING

Single-centre, KK Women's and Children's Hospital, Singapore.

PATIENTS: Two hundred and thirty-six healthy women undergoing elective caesarean delivery under spinal anaesthesia.

MAIN OUTCOME MEASURES: The primary outcome was the incidence of maternal hypotension. The secondary outcome measures were reactive hypertension, total vasopressor requirement and maternal and neonatal outcomes.

RESULTS

The DIVA group had a significantly lower incidence of maternal hypotension, with 39.3% (46 of 117) patients having any SBP reading less than 80% of baseline compared with 57.5% (65 of 113) in the manual vasopressor bolus group (P = 0.008). The DIVA group also had fewer hypotensive episodes than the manual vasopressor bolus group (4.67 versus 7.77%; P < 0.0001). There was no difference in the incidence of reactive hypertension or the total vasopressor requirement. The DIVA group had less wobble in system performance. Maternal and neonatal outcomes were similar.

CONCLUSION

The DIVA system achieved better control of maternal blood pressure after spinal anaesthesia than manual vasopressor bolus administration.

TRIAL REGISTRATION: Clinicaltrials.gov identifier: NCT02277730.

Для цитирования: Sng Ban Leong, Du Wei, Lee Man Xin, Ithnin Farida, Mathur Deepak, Leong Wan Ling, Sultana Rehena, Han Nian-Lin R, Sia Alex Tiong Heng. Comparison of double intravenous vasopressor automated system using nexfin versus manual vasopressor bolus administration for maintenance of haemodynamic stability during spinal anaesthesia for caesarean delivery: A randomised double-blind controlled trial.. European journal of anaesthesiology. 2018. DOI: 10.1097/eja.0000000000000779.