MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jmri.23793

Медицинская библиотека · Journal of magnetic resonance imaging : JMRI · 2012

Four-dimensional velocity-encoded magnetic resonance imaging improves blood flow quantification in patients with complex accelerated flow.

Nordmeyer Sarah, Riesenkampff Eugénie, Messroghli Daniel, Kropf Siegfried, Nordmeyer Johannes, Berger Felix, Kuehne Titus

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To evaluate the use of four-dimensional (4D) velocity-encoded magnetic resonance imaging (VEC MRI) for blood flow quantification in patients with semilunar valve stenosis and complex accelerated flow.

MATERIALS AND

METHODS

Peak velocities (Vmax) and stroke volumes (SV) were quantified by 2D and 4D VEC MRI in volunteers (n = 7) and patients with semilunar valve stenosis (n = 18). Measurements were performed above the aortic and pulmonary valve with both techniques and, additionally, at multiple predefined planes in the ascending aorta and in the pulmonary trunk within the 4D dataset. In patients, 4D VEC MRI streamline analysis identified flow patterns and regions of highest flow velocity (4D(max-targeted)) for further measurements and Vmax was also measured by Doppler-echocardiography.

RESULTS

In patients, 4D VEC MRI showed higher Vmax than 2D VEC MRI (2.7 ± 0.6 m/s vs. 2.4 ± 0.5 m/s, P < 0.03) and was more comparable to Doppler-echocardiography (2.8 ± 0.7 m/s). 4D(max-targeted) revealed highest Vmax values (3.1 ± 0.6 m/s). SV measurements showed significant differences between different anatomical levels in the ascending aorta in patients with complex accelerated flow, whereas differences in volunteers with laminar flow patterns were negligible (P = 0.004).

CONCLUSION

4D VEC MRI improves MRI-derived blood flow quantification in patients with semilunar valve stenosis and complex accelerated flow.

Для цитирования: Nordmeyer Sarah, Riesenkampff Eugénie, Messroghli Daniel, Kropf Siegfried, Nordmeyer Johannes, Berger Felix, Kuehne Titus. Four-dimensional velocity-encoded magnetic resonance imaging improves blood flow quantification in patients with complex accelerated flow.. Journal of magnetic resonance imaging : JMRI. 2012. DOI: 10.1002/jmri.23793.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.