MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12886-023-03213-8

Медицинская библиотека · BMC ophthalmology · 2023

Spontaneous resolution of long-standing choroidal effusion after glaucoma drainage implant surgery without significant visual deterioration : a case report.

Sung Mi Sun, Lee Jong Hoon, Ji Yong-Sok, Park Sang Woo

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Choroidal effusion is a common complication of glaucoma surgery. Although most cases of choroidal effusions resolve spontaneously with observation or medical management alone as intraocular pressure normalizes, surgical drainage might be needed in severe or persistent cases. Herein, we report a case of spontaneous resolution of long-standing severe choroidal effusion after Ahmed glaucoma valve implantation.

CASE PRESENTATION: An 85-year-old man with uncontrolled primary open-angle glaucoma and medical history of chronic kidney disease underwent uneventful Ahmed glaucoma valve implantation. On postoperative day 8, transient hypotony occurred, and large 360° peripheral choroidal detachments developed. Although the intraocular pressure increased to normal levels on postoperative day 15, choroidal effusion did not resolve. Fundus examination over 8 months showed that the large choroidal effusion persisted despite a well-controlled intraocular pressure. Laboratory test performed at preoperatively and follow-up period revealed persistently elevated potassium and creatinine levels. On postoperative 9 months, the lesion resolved spontaneously without any surgical intervention. We found that the patient's creatinine level was normalized, pre-existing hyperkalemia was corrected, and accordingly his general condition was improved.

CONCLUSIONS

Considering the underlying medical condition may be helpful in patients with persistent choroidal effusion of an unclear etiology following glaucoma filtering surgery.

Для цитирования: Sung Mi Sun, Lee Jong Hoon, Ji Yong-Sok, Park Sang Woo. Spontaneous resolution of long-standing choroidal effusion after glaucoma drainage implant surgery without significant visual deterioration : a case report.. BMC ophthalmology. 2023. DOI: 10.1186/s12886-023-03213-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.