MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jhsa.2018.10.008

Медицинская библиотека · The Journal of hand surgery · 2018

A Comparison Between Two Collagen Nerve Conduits and Nerve Autograft: A Rat Model of Motor Nerve Regeneration.

Saltzman Eliana B, Villa Jordan C, Doty Stephen B, Feinberg Joseph H, Lee Steve K, Wolfe Scott W

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: To compare recovery in a rat model of sciatic nerve injury using a novel polyglycolic acid (PGA) conduit, which contains collagen fibers within the tube, as compared with both a hollow collagen conduit and nerve autograft. We hypothesize that a conduit with a scaffold will provide improved nerve regeneration over hollow conduits and demonstrate no significant differences when compared with autograft.

METHODS

A total of 72 Sprague-Dawley rats were randomized into 3 experimental groups, in which a unilateral 10-mm sciatic defect was repaired using either nerve autograft, a hollow collagen conduit, or a PGA collagen-filled conduit. Outcomes were measured at 12 and 16 weeks after surgery, and included bilateral tibialis anterior muscle weight, voltage and force maximal contractility, assessment of ankle contracture, and nerve histology.

RESULTS

In all groups, outcomes improved between 12 and 16 weeks. On average, the autograft group outperformed both conduit groups, and the hollow conduit demonstrated improved outcomes when compared with the PGA collagen-filled conduit. Differences in contractile force, however, were significant only at 12 weeks (autograft > hollow collagen conduit > PGA collagen-filled conduit). At 16 weeks, contractile force demonstrated no significant difference but corroborated the same absolute results (autograft > hollow collagen conduit > PGA collagen-filled conduit).

CONCLUSIONS

Nerve repair using autograft provided superior motor nerve recovery over the 2 conduits for a 10-mm nerve gap in a murine acute transection injury model. The hollow collagen conduit demonstrated superior results when compared with the PGA collagen-filled conduit.

CLINICAL RELEVANCE: The use of a hollow collagen conduit provides superior motor nerve recovery as compared with a PGA collagen-filled conduit.

Для цитирования: Saltzman Eliana B, Villa Jordan C, Doty Stephen B, Feinberg Joseph H, Lee Steve K, Wolfe Scott W. A Comparison Between Two Collagen Nerve Conduits and Nerve Autograft: A Rat Model of Motor Nerve Regeneration.. The Journal of hand surgery. 2018. DOI: 10.1016/j.jhsa.2018.10.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.