m+Medelevator.RU
← Поиск публикаций
Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association · 2011

Dynamic imaging and function of partial supraspinatus tendon tears.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Gerber Christian, Zubler Veronika, Hodler Jürg, Catanzaro Sabrina, Jost Bernhard, Fucentese Sandro F

Аннотация

PURPOSE: It was the purpose of this study to identify and document normal and abnormal supraspinatus tendon function in vivo using real-time ultrasound.

METHODS: We defined 4 groups of 20 individuals each: partial tear (group 1), full-thickness tear (group 2), successfully repaired tear (group 3), and healthy asymptomatic controls (group 4). Except for group 4, all patients underwent magnetic resonance arthrography to confirm the diagnosis. All underwent ultrasound imaging of the supraspinatus tendon with the adducted arm at rest and under maximal isometric abduction. Tendon deformation was dynamically assessed and measured with tendon thickness changes at 0.5, 1, 1.5, and 2 cm from the tendon insertion. The clinical assessment consisted of absolute and relative Constant score, subjective shoulder value, and strength measurements.

RESULTS: Without muscle contraction, the tendons of the 4 groups were not of significantly different thickness, with the least variation at 1.5 cm from the insertion site. On contraction, the normal tendon thickness significantly increased at a distance of 2 cm, whereas it did not for the full-thickness and partial supraspinatus tears. Thus contraction of the muscle resulted in measurable deformation of the tendon.

CONCLUSIONS: Partially torn supraspinatus tendons can be functionally incompetent, leading to a biomechanical deformation of the musculotendinous unit that is not different from that of a unit with a full-thickness tendon tear. The dynamic sonographic finding of a successful repair of a supraspinatus tendon is similar to that of a normal tendon, even though the previously injured muscle appears unable to generate the same strength as a normal muscle.

LEVEL OF EVIDENCE: Level III, case-control study.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты