MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00005131-200101000-00011

Медицинская библиотека · Journal of orthopaedic trauma · 2001

Partridge osteosynthesis: a prospective clinical study on the use of nylon cerclage bands and plates in the treatment of periprosthetic femoral shaft fractures.

de Ridder V A, de Lange S, Koomen A R, Heatley F W

Клиническое исследованиеСравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the clinical use of the Partridge osteosynthesis in periprosthetic femoral fractures.

DESIGN AND

SETTING

Prospective nonrandomized clinical study.

PATIENTS: Over a ten-year period, 222 patients presenting with femoral fractures near the tip of a hip prosthesis were treated with the Partridge system, which employs elevated cerclage nylon bands and flexible elevated nylon plates. Sixty-five fractures were located cranial to the tip of the prosthesis (Whittaker Type I), 116 at the tip (type II), and forty-one distal to the tip of the prosthesis (Type III). The population consisted of 172 female and fifty male patients, with a mean age of 79.5 years. The mean duration between the index procedure and occurrence of the second fracture was 1.5 years. In 78 percent of the patients (173 out of 222), surgery was undertaken within forty-eight hours. Fracture reduction was open, and two nylon plates set at right angles to each other were secured to the femur with six to eight nylon bands. The mean operating time was fifty-five minutes, with an average blood loss of 550 milliliters.

RESULTS

There were minor wound healing problems in eighteen patients (12.6 percent); there were no deep wound infections. Thirty-three elderly patients died within the first month from medical complications. Of the 189 remaining patients, 60 percent regained their prefracture functional level within six months postoperatively, whereas 25 percent required a higher level of care. The mean time of the in-hospital stay was thirty-three days. Ninety-three percent of the fractures consolidated with abundant callus during the follow-up period of one year.

CONCLUSION

The indication for the use of this simple osteosynthesis method is swift convalescence by splinting the periprosthetic femoral fractures. Even with a loose prosthesis, the fracture often healed with abundant callus and the patient could be mobilized.

Для цитирования: de Ridder V A, de Lange S, Koomen A R, Heatley F W. Partridge osteosynthesis: a prospective clinical study on the use of nylon cerclage bands and plates in the treatment of periprosthetic femoral shaft fractures.. Journal of orthopaedic trauma. 2001. DOI: 10.1097/00005131-200101000-00011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.