OBJECTIVE

To investigate the association between false lumen (FL) dependency of segmental arteries (SAs) at T9-L3 levels and the risk of spinal cord injury (SCI) following total arch replacement and frozen elephant trunk (FET) implantation in the setting of acute DeBakey type I aortic dissection (AAD).

METHODS

The study involved consecutive patients with AAD who underwent total arch replacement and FET implantation between 2020 and 2022. Primary outcome was postoperative SCI. The inverse probability of treatment weighting (IPTW) method was employed to minimize the impact of no-randomization bias. Antegrade placement of FET was followed by end-to-end anastomosis of a 4-branch arch graft at the proximal landing site of FET.

RESULTS

A total of 146 patients were included (age, 50.5 ± 11.7 years, 115 male), of whom 35 (24%) had SAs at T9-L3 levels completely dependent on FL (FL-dependency group). There was no significant difference in early (30-day or in-hospital) mortality rates between FL-dependency (14.3%) and FL-independency (18.0%) groups (P = .80), however, the rate of SCI was significantly higher in the FL-Dependency group (34.3% vs 2.7%, P < .001). After adjustments, FL dependency was associated with a significantly increased risk of SCI (odds ratio, 13.1; 95% confidence interval, 4.2-41.0; P < .001), whereas it was not significantly associated with risks of early mortality or other major complications (P = .16-.98).

CONCLUSIONS

FL dependency of SAs at the T9-L3 levels was significantly associated with the development of SCI following FET implantation in AAD, warning against its uses on patients presenting with FL dependency of SAs at critical segments.

Для цитирования: Dong Zhiqiang, Liu Hong, Kim Joon Bum, Gu Jiaxi, Li Minghui, Li Gang, Du Junjie, Gu Weidong, Shao Yongfeng, Ni Buqing. False lumen-dependent segmental arteries are associated with spinal cord injury in frozen elephant trunk procedure for acute type I aortic dissection.. JTCVS open. 2023. DOI: 10.1016/j.xjon.2023.05.014.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.