DOI 10.1016/j.jcms.2013.07.005

Медицинская библиотека · Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery · 2013

3D vector analysis of mandibular condyle stability in mandibular setback surgery with bicortical bioabsorbable screw fixation.

Lee Jee Ho, Kim Soung Min, Lee Bu Kyu, Jeon Ju Hong, Kim Myung Jin

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Bioabsorbable screws became widely used for stable fixation in orthognathic surgery as biomechanical technology advanced. Recently, 3D image analyses begin to be used to evaluate surgical changes. The purpose of this study was to evaluate, using 3D vector analysis, the stability of bicortical bioabsorbable screw fixation in mandibular setback using a sagittal split ramus osteotomy. Spatial change of the mandibular condyle was determined by 3D coordinates containing directional information.

MATERIALS AND

METHODS

Bicortical screw fixation was performed using either a bioabsorbable screw (25 patients) or a titanium screw (5 patients) in orthognathic surgery. Pre- and post-operative CT images (6 months after surgery) were superimposed digitally. A 3D coordinate (X, Y, Z) and vectors were employed to quantify spatial changes of the condyle and analysed statistically.

RESULTS

Measuring on 3D image showed stable error about 0.16 mm. There were no significant differences in the total spatial changes of the condyle between titanium and bioabsorbable screws with the exception of the lateral-medial direction of the condylar centre (P = 0.042). The directional vector components were stable, regardless of mandibular setback.

CONCLUSION

In 3D vector analysis, bioabsorbable screw fixation in SSRO with distal segment osteotomy shows clinically acceptable postoperative condylar position stability.

Для цитирования: Lee Jee Ho, Kim Soung Min, Lee Bu Kyu, Jeon Ju Hong, Kim Myung Jin. 3D vector analysis of mandibular condyle stability in mandibular setback surgery with bicortical bioabsorbable screw fixation.. Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery. 2013. DOI: 10.1016/j.jcms.2013.07.005.