BACKGROUND

A simple and powerful microextraction procedure, the solvent bar microextraction (SBME), was used for the simultaneous determination of two diuretics, furosemide and spironolactone in human urine and plasma samples, using high-performance liquid chromatography coupled with diode array detection (HPLC-DAD).

METHODS

The appropriate amount (2 μL) of 1-octanol as an organic solvent confined within 2.5 cm of a porous hollow fiber micro-tube, sealed at both ends was used for this procedure. The conditions for the SBME were optimized in water and the analytical performance was examined in spiked human urine and plasma samples.

RESULTS

The optimized method exhibited good linearity (R2> 0.997) over the studied range of higher than 33 to 104μg L-1 for furosemide and spironolactone in urine and plasma samples, illustrating a satisfactory precision level with RSD values between 2.1% and 9.1%.

DISCUSSION: The values of the limits of detection were found to be in the range of 6.39 to 9.67μg L-1, and extraction recovery ˃ 58.8% for both diuretics in urine and plasma samples. The applicability and effectiveness of the proposed method for the determination of furosemide and spironolactone in patient urine samples were tested.

CONCLUSION

In comparison with reference methods, the attained results demonstrated that SBME combined with HPLC-DAD was proved to be simple, inexpensive, and promising analytical technology for the simultaneous determination of furosemide and spironolactone in urine and plasma samples.

Для цитирования: Al-Hashimi Nabil N, El-Sheikh Amjad H, Alruwad Manal I, Odeh Mohanad M. Solvent Bar Microextraction Combined with HPLC-DAD for Simultaneous Determination of Diuretics in Human Urine and Plasma Samples.. Current pharmaceutical biotechnology. 2022. DOI: 10.2174/1389201022666210222111943.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.