MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1088/1361-6560/ae9b59

Медицинская библиотека · Physics in medicine and biology · 2026

A 2πsolid angle-based heuristic framework for non-coplanar VMAT in multiple brain metastases.

Huang Shixiong, Yang Songhua, Dong Yang, Huang Sheng, Li Xiaohua, Zeng Biao

СтатьяПеревод в очереди

Аннотация

Objective.This study proposes a 2πsolid angle-based heuristic framework for non-coplanar volumetric modulated arc therapy (VMAT) in patients with multiple brain metastases (MBM) to automate treatment angle selection.Approach.Fifty-two patients with MBM (2-8 targets) were retrospectively included. A hybrid heuristic framework was constructed: first, a volume-weighted cumulative tumor-skin distance (VW-CTSD) metric was introduced to quantify geometric requirements in the 2πsolid angle space and to automatically identify non-coplanar trajectories minimizing normal brain exposure. Subsequently, a blocking factor-based sub-arc segmentation and collimator-angle selection strategy determined the sub-arc splitting and collimator angles. Using 30 Gy/5 fractions, three plans were generated for each patient: manual expert planning (Pref), VW-CTSD-guided trajectory selection alone (Ptsd), and the proposed combined heuristic strategy (Pcom). Dosimetric metrics and plan parameters were compared.Main results.All plans met clinical goals.Ptsdachieved automated trajectory selection with plan quality comparable toPref. Values are presented as median (P25-P75). Compared withPref,Pcomimproved CI [0.86 (0.85-0.89) to 0.89 (0.85-0.91)] and reduced GI [3.37 (3.17-3.79) to 3.09 (2.74-3.48)].Pcomalso reduced normal brain tissue (NBT)V12Gy, MU, and CM from 92.45 (62.54-141.46) to 83.57 (50.30-125.10) cc, from 2391 (2144-2527) to 1938 (1845-2085), and from 0.22 (0.21-0.24) to 0.20 (0.19-0.21), respectively. Control-point aperture analysis showedX-axis narrowing [129.75 (110.60-146.35) to 101.91 (83.34-120.20) mm] andY-axis expansion [98.70 (80.13-105.86) to 119.17 (103.38-133.48) mm] inPcom. AllPcom-versus-Prefcomparisons for these metrics were statistically significant (P< 0.001).Significance.The proposed combined heuristic framework reduced NBT dose, GI, MU, and CM, suggesting its potential as a practical automated approach for non-coplanar VMAT angle selection in patients with MBM.

Для цитирования: Huang Shixiong, Yang Songhua, Dong Yang, Huang Sheng, Li Xiaohua, Zeng Biao. A 2πsolid angle-based heuristic framework for non-coplanar VMAT in multiple brain metastases.. Physics in medicine and biology. 2026. DOI: 10.1088/1361-6560/ae9b59.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.