MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajem.2016.10.085

Медицинская библиотека · The American journal of emergency medicine · 2016

Real-time tidal volume feedback guides optimal ventilation during simulated CPR.

You Kyoung Min, Lee Chiwon, Kwon Woon Yong, Lee Jung Chan, Suh Gil Joon, Kim Kyung Su, Park Min Ji, Kim Sungwan

СтатьяПеревод в очереди

Аннотация

PURPOSE: We performed this study to investigate whether real-time tidal volume feedback increases optimal ventilation and decreases hyperventilation during manikin-simulated cardiopulmonary resuscitation (CPR).

BASIC PROCEDURES: We developed a new real-time tidal volume monitoring device (TVD) which estimated tidal volume in real time using a magnetic flowmeter. The TVD was validated with a volume-controlled mechanical ventilator with various tidal volumes. We conducted a randomized, crossover, manikin-simulation study in which 14 participants were randomly divided into a control (without tidal volume feedback, n = 7) and a TVD group (with real-time tidal volume feedback, n = 7) and underwent manikin simulation. The optimal ventilation was defined as 420-490 mL of tidal volumes for a 70-kg adult manikin. After 2 weeks of the washout period, the simulation was repeated via the participants' crossover.

MAIN FINDINGS: In the validation study, 97.6% and 100% of the difference ratios in tidal volumes between the mechanical ventilator and TVD were within ±1.5% and ±2.5%, respectively. During manikin-simulated CPR, TVD use increased the proportion of optimal ventilation per person. Its median values (range) of the control group and the TVD group were 37.5% (0.0-65.0) and 87.5% (65.0-100.0), respectively, P < .001). TVD use also decreased hyperventilation. The proportions of hyperventilation in the control group and the TVD group were 25.0% vs 8.9%, respectively (P < .001).

PRINCIPAL

CONCLUSIONS

Real-time tidal volume feedback using the new TVD guided the rescuers to provide optimal ventilation and to avoid hyperventilation during manikin-simulated CPR.

Для цитирования: You Kyoung Min, Lee Chiwon, Kwon Woon Yong, Lee Jung Chan, Suh Gil Joon, Kim Kyung Su, Park Min Ji, Kim Sungwan. Real-time tidal volume feedback guides optimal ventilation during simulated CPR.. The American journal of emergency medicine. 2016. DOI: 10.1016/j.ajem.2016.10.085.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.