MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.brachy.2025.07.012

Медицинская библиотека · Brachytherapy · 2025

Evaluation of variability in applicator position and organs at risk dose in fractionated intracavitary brachytherapy for cervical cancer.

Kazoba Francis, Sauli Elingarami, Nyanza Elias, Amasi Aloyce I

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Cervical cancer remains a major cause of mortality in low- and middle-income countries (LMICs). Intracavitary brachytherapy (ICBT) is critical for curative radiotherapy; however, inter-fractional variability in applicator positioning may compromise treatment reproducibility and organ-at-risk (OAR) sparing.

OBJECTIVE

This study assessed inter-fractional applicator positional stability and its dosimetric impact on OARs during fractionated ICBT for cervical cancer.

MATERIALS AND

METHODS

A prospective analysis of 60 treatment plans from 20 patients receiving three ICBT fractions was conducted. Applicator shifts along the X, Y, and Z axes and corresponding bladder and rectal doses were evaluated. Descriptive statistics and repeated measures ANOVA determined positional reproducibility and dose variability, while correlation analysis examined associations between applicator displacement and OAR dose changes.

RESULTS

Applicator positioning was reproducible across fractions, with no significant differences in any axis p > 0.05). Bladder dose, however, demonstrated significant variation (p = 0.027), progressively increasing across fractions. Moderate correlations (r ≈ 0.39) were observed between bladder dose escalation and applicator shifts along the X and Y axes, especially in the Y-axis. Rectal dose remained stable (p = 0.776).

CONCLUSION

Although applicator positioning was geometrically stable, significant bladder dose variability occurred. Adaptive replanning and real-time imaging are recommended to optimize treatment precision in fractionated ICBT.

Для цитирования: Kazoba Francis, Sauli Elingarami, Nyanza Elias, Amasi Aloyce I. Evaluation of variability in applicator position and organs at risk dose in fractionated intracavitary brachytherapy for cervical cancer.. Brachytherapy. 2025. DOI: 10.1016/j.brachy.2025.07.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.