MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5662/wjm.v13.i5.502

Медицинская библиотека · World journal of methodology · 2023

Successful hip revision surgery following refracture of a modern femoral stem using a cortical window osteotomy technique: A case report and review of literature.

Lucero Carlos M, Luco Juan B, Garcia-Mansilla Agustin, Slullitel Pablo A, Zanotti Gerardo, Comba Fernando, Buttaro Martin A

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

The ExeterTM Universal cemented femoral component is widely used for total hip replacement surgery. Although there have been few reports of femoral component fracture, removal of a broken femoral stem can be a challenging procedure.

CASE SUMMARY: A 54-year-old man with a Dorr A femur sustained a refracture of a primary ExeterTM stem, two years after receiving a revision using a cement-within-cement technique (CWC) through an extended trochanteric osteotomy (ETO). The technical problems related to the CWC technique and the ETO played a major role in the stem fatigue refracture. We performed revision surgery and removed the distal cement using a cortical femoral window technique, followed by re-implantation with an uncemented, modular, distally-fixed uncemented stem. The patient experienced an uneventful postoperative recovery.

CONCLUSION

Re-fracture of a modern femoral ExeterTM stem is a rare event, but technical complications related to revision surgery can lead to this outcome. The cortical window osteotomy technique can facilitate the removal of a broken stem and cement, allowing for prosthetic re-implantation under direct vision and avoiding ETO-related complications.

Для цитирования: Lucero Carlos M, Luco Juan B, Garcia-Mansilla Agustin, Slullitel Pablo A, Zanotti Gerardo, Comba Fernando, Buttaro Martin A. Successful hip revision surgery following refracture of a modern femoral stem using a cortical window osteotomy technique: A case report and review of literature.. World journal of methodology. 2023. DOI: 10.5662/wjm.v13.i5.502.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.