Pre-procedural femoral vessel ultrasound in dogs with patent ductus arteriosus: diameter, image quality and relationship with arterial catheterization.
Аннотация
INTRODUCTION
Objectives
Patent ductus arteriosus (PDA) in dogs is often treated via minimally invasive transvascular occlusion using femoral artery access. This study compared ultrasound-derived diameter and image quality of the right femoral artery (RFA) and vein (RFV) in dogs with PDA using a linear ultrasound probe (L-P) and phased-array transthoracic echocardiography probe (TTE-P). The case outcome was assessed.
ANIMALS, MATERIALS &
METHODS
Forty-five client-owned dogs with PDA were prospectively enrolled. Ultrasound-measured RFA and RFV diameters were obtained on images acquired with both probes pre-operatively and compared using Bland-Altman plots. The image quality of RFA and RFV was scored on L-P and TTE-P images.
RESULTS
Comparison of RFA and RFV diameter from L-P versus TTE-P images revealed: [Mean difference (limits of agreement): RFA = 0.009 mm (-0.78-0.79 mm), RFV = 0.523 mm (-1.75-2.79 mm)]. Image quality scores were significantly higher for L-P than TTE-P (P < 0.0001). In six small dogs, measurable images were unattainable with TTE-P. Dogs of similar body weight had variable RFA diameters. Twenty-seven dogs had RFA catheterization. In 21/27 dogs, RFA diameter exceeded the external diameter of the introducer used for catheterization, and in 6/27, it was smaller.
CONCLUSIONS
Pre-procedural ultrasound of the RFA in dogs with PDA is useful given variable RFA diameter relative to body weight. Despite poorer image quality, RFA diameters from TTE-P images were very similar to L-P images on average, suggesting TTE-Ps are suitable for pre-procedural planning in most dogs. Vasospasm, hypotension or differences in the location of ultrasound measurement versus catheterization might produce variation in pre-procedural versus intraoperative RFA size.