PloS one · 2021
Validation of color Doppler ultrasound and computed tomography in the radiologic assessment of non-malignant acute splanchnic vein thrombosis.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Sturm Lukas, Bettinger Dominik, Klinger Christoph, Krauss Tobias, Engel Hannes, Huber Jan Patrick, Schmidt Arthur, Caca Karel, Thimme Robert, Schultheiss Michael
Аннотация
INTRODUCTION: International guidelines propose color Doppler ultrasound (CDUS) and contrast-enhanced computed tomography (CT) as primary imaging techniques in the diagnosis of acute splanchnic vein thrombosis. However, their reliability in this context is poorly investigated. Therefore, the aim of our study was to validate CDUS and CT in the radiologic assessment of acute splanchnic vein thrombosis, using direct transjugular spleno-portography as gold standard.
MATERIALS AND METHODS: 49 patients with non-malignant acute splanchnic vein thrombosis were included in a retrospective, multicenter analysis. The thrombosis' extent in five regions of the splanchnic venous system (right and left intrahepatic portal vein, main trunk of the portal vein, splenic vein, superior mesenteric vein) and the degree of thrombosis (patent, partial thrombosis, complete thrombosis) were assessed by portography, CDUS and CT in a blinded manner. Reliability of CDUS and CT with regard to portography as gold standard was analyzed by calculating Cohen's kappa.
RESULTS: Results of CDUS and CT were consistent with portography in 76.6% and 78.4% of examinations, respectively. Cohen's kappa demonstrated that CDUS and CT delivered almost equally reliable results with regard to the portographic gold standard (k = 0.634 [p < 0.001] vs. k = 0.644 [p < 0.001]). In case of findings non-consistent with portography there was no clear trend to over- or underestimation of the degree of thrombosis in both CDUS (60.0% vs. 40.0%) and CT (59.5% vs. 40.5%).
CONCLUSIONS: CDUS and CT are equally reliable tools in the radiologic assessment of non-malignant acute splanchnic vein thrombosis.
MATERIALS AND METHODS: 49 patients with non-malignant acute splanchnic vein thrombosis were included in a retrospective, multicenter analysis. The thrombosis' extent in five regions of the splanchnic venous system (right and left intrahepatic portal vein, main trunk of the portal vein, splenic vein, superior mesenteric vein) and the degree of thrombosis (patent, partial thrombosis, complete thrombosis) were assessed by portography, CDUS and CT in a blinded manner. Reliability of CDUS and CT with regard to portography as gold standard was analyzed by calculating Cohen's kappa.
RESULTS: Results of CDUS and CT were consistent with portography in 76.6% and 78.4% of examinations, respectively. Cohen's kappa demonstrated that CDUS and CT delivered almost equally reliable results with regard to the portographic gold standard (k = 0.634 [p < 0.001] vs. k = 0.644 [p < 0.001]). In case of findings non-consistent with portography there was no clear trend to over- or underestimation of the degree of thrombosis in both CDUS (60.0% vs. 40.0%) and CT (59.5% vs. 40.5%).
CONCLUSIONS: CDUS and CT are equally reliable tools in the radiologic assessment of non-malignant acute splanchnic vein thrombosis.