MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12883-022-02565-w

Медицинская библиотека · BMC neurology · 2022

A score of non-contrast transthoracic echocardiography to screen patent foramen ovale in patients with embolic stroke of undetermined source.

Zhang Hui, Tang Haiyan, Wu Fei, Yu Chun, Dong Qiang, Cao Wenjie

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The aim of this study was to develop a screening score system of non-contrast transthoracic echocardiography (TTE) for patent foramen ovale (PFO) in patients with embolic stroke of undetermined source (ESUS).

METHODS

We performed a retrospective analysis of 218 consecutive patients with a recent ESUS from 2015 to 2018, who received TTE and transcranial Doppler (TCD) as routine examinations. PFO was diagnosed by the bubble test of TCD. Significant differences of the non-contrast TTE findings and patient characteristics between PFO group and non-PFO group were selected into a score.

RESULTS

PFO was diagnosed in 35.8% (78/218) of the patients. Compared with non-PFO group, a larger median aortic root diameter (ARd) (34 mm vs. 32 mm, p = 0.005), a lower median peak E wave velocity (Em) (61.5 cm/s vs. 68 cm/s, p = 0.005) and a lower incidence rate of mitral regurgitation (34.6% vs. 50.7%, p = 0.022) were seen in PFO group. ARd>33 mm and Em < 72 cm/s were the best thresholds to predict PFO in ROC analysis. A four-point score system (MEAD) including TTE criteria (including ARd>33 mm, Em < 72 cm/s and without mitral regurgitation) and no history of diabetes predicted PFO with an area under curve of 0.67 (95%CI 0.57-0.72, p < 0.001). MEAD score ≥ 3 was the best threshold to predict PFO with an accuracy of 0.64 (95% CI 0.57-0.7), a sensitivity of 0.65 (95% CI 0.53-0.75) and a specificity of 0.63 (95% CI 0.55-0.71).

CONCLUSION

The MEAD score measured with non-contrast TTE can be used to select patients for bubble test of TCD to increase the diagnostic yield of PFO after ESUS.

Для цитирования: Zhang Hui, Tang Haiyan, Wu Fei, Yu Chun, Dong Qiang, Cao Wenjie. A score of non-contrast transthoracic echocardiography to screen patent foramen ovale in patients with embolic stroke of undetermined source.. BMC neurology. 2022. DOI: 10.1186/s12883-022-02565-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.