DOI 10.1097/olq.0000000000000993
Evaluation of a Rapid Syphilis Test in an Emergency Department Setting in Detroit, Michigan.
Аннотация
BACKGROUND
Syphilis transmission can be prevented by prompt diagnosis and treatment of primary and secondary infection. We evaluated the performance of a point-of-care rapid syphilis treponemal (RST) test in an emergency department (ED) setting.
METHODS
Between June 2015 and April 2016, men aged 18 to 34 years seeking services in a Detroit ED, and with no history of syphilis, were screened for syphilis with the RST test, rapid plasma reagin (RPR) test, and Treponema pallidum particle agglutination assay (TP-PA). A positive reference standard was both a reactive RPR and a reactive TP-PA. We compared test results in self-reported men who have sex with men (MSM) to non-MSM.
RESULTS
Among 965 participants, 10.9% of RST tests were reactive in MSM and only 1.5% in non-MSM (P < 0.001). Sensitivity of the RST test was 76.9% and specificity was 99.0% (positive predictive value, 50.0%) compared with the positive reference standard. Three discordant specimens found negative with the RST test but positive with the reference standard had an RPR titer of 1:1, compared with 10 specimens with concordant positive results that had a median RPR titer of 1:16. The RST sensitivity was 50.0% (positive predictive value, 68.4%) compared to the TP-PA test alone. Among men seeking care in an ED, the RST detected 76.9% of participants with a reactive RPR and TP-PA.
CONCLUSIONS
The RST test detected all of the participants with an RPR titer ≥1:2 but less than 20% of participants with a positive TP-PA and negative RPR. The RST test was useful to detect a high proportion of participants with an active syphilis in an urban ED.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.