m+Medelevator.RU
← Поиск публикаций
International journal of STD & AIDS · 2018

Field performance evaluation of dual rapid HIV and syphilis tests in three antenatal care clinics in Zambia.

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kasaro Margaret P, Bosomprah Samuel, Taylor Melanie M, Sindano Ntazana, Phiri Caroline, Tambatamba Bushimbwa, Malumo Sarai, Freeman Bethany, Chibwe Bertha, Laverty Maura, Owiredu Morkor N, Newman Lori, Sikazwe Izukanji

Аннотация

This cross-sectional study of 3212 pregnant women assessed the field performance, acceptability, and feasibility of two dual HIV/syphilis rapid diagnostic tests, the Chembio DPP HIV-syphilis Assay and the SD Bioline HIV/syphilis Duo in antenatal clinics. Sensitivity and specificity for HIV and syphilis were calculated compared to the rapid Determine HIV-1/2 with Uni-Gold to confirm positive results for HIV and the Treponema pallidum particle agglutination assay for syphilis. RPR titers ≥1:4 were used to define active syphilis detection. Acceptability and feasibility were assessed using self-reported questionnaires. For Chembio, the HIV sensitivity was 90.6% (95%CI = 87.4, 93.0) and specificity was 97.2% (95%CI = 96.2, 97.8); syphilis sensitivity was 68.6% (95%CI = 61.9, 74.6) and specificity was 98.5% (95%CI = 97.8, 98.9). For SD Bioline, HIV sensitivity was 89.4% (95%CI = 86.1, 92.0) and specificity was 96.3% (95%CI = 95.3, 97.1); syphilis sensitivity was 66.2% (95%CI = 59.4, 72.4) and specificity was 97.2% (95%CI = 96.4, 97.9). Using the reference for active syphilis, syphilis sensitivity was 84.7% (95%CI = 76.1, 90.6) for Chembio and 81.6% (95%CI = 72.7, 88.1) for SD Bioline. Both rapid diagnostic tests were assessed as highly acceptable and feasible. In a field setting, the performance of both rapid diagnostic tests was comparable to other published field evaluations and each was rated highly acceptable and feasible. These findings can be used to guide further research and proposed scale up in antenatal clinic settings.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты