International orthopaedics · 2016
Radiographic templating of total hip arthroplasty for femoral neck fractures.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Lakstein Dror, Bachar Ira, Debi Ronen, Lubovsky Omri, Cohen Ornit, Tan Zachary, Atoun Ehud
Аннотация
PURPOSE: The purpose of this study was to evaluate the use of pre-operative digital templating to minimize complications including limb length discrepancy (LLD), intraoperative fractures and early dislocations in patients with intracapsular femoral neck fractures.
METHODS: We retrospectively compared 23 patients undergoing total hip arthroplasty (THA) for intracapsular femoral fractures with pre-operative digital templating and 48 patients without templating.
RESULTS: The mean post-operative LLD was significantly lower in patients who had pre-operative templating than in the control group (6.7 vs. 11.5 mm, p = 0.023). Only three patients (13 %) with templating had LLD greater than 1.5 cm, compared to the 15 patients (31 %) without templating (p = 0.17). In eight cases the final femoral stem size matched the templated size, while 19 patients were within two size increments. Complications included one dislocation and one intra-operative fracture in the control group.
CONCLUSION: The present study demonstrated that careful pre-operative planning may reduce LLD in patients undergoing THA due to intracapsular hip fractures.
METHODS: We retrospectively compared 23 patients undergoing total hip arthroplasty (THA) for intracapsular femoral fractures with pre-operative digital templating and 48 patients without templating.
RESULTS: The mean post-operative LLD was significantly lower in patients who had pre-operative templating than in the control group (6.7 vs. 11.5 mm, p = 0.023). Only three patients (13 %) with templating had LLD greater than 1.5 cm, compared to the 15 patients (31 %) without templating (p = 0.17). In eight cases the final femoral stem size matched the templated size, while 19 patients were within two size increments. Complications included one dislocation and one intra-operative fracture in the control group.
CONCLUSION: The present study demonstrated that careful pre-operative planning may reduce LLD in patients undergoing THA due to intracapsular hip fractures.