MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/eja.0000000000000690

Медицинская библиотека · European journal of anaesthesiology · 2017

The impact of continuous non-invasive arterial blood pressure monitoring on blood pressure stability during general anaesthesia in orthopaedic patients: A randomised trial.

Meidert Agnes S, Nold Johanna S, Hornung Roman, Paulus Alexander C, Zwißler Bernhard, Czerner Stephan

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

In patients undergoing general anaesthesia, intraoperative hypotension occurs frequently and is associated with adverse outcomes such as postoperative acute kidney failure, myocardial infarction or stroke. A history of chronic hypertension renders patients more susceptible to a decrease in blood pressure (BP) after induction of general anaesthesia. As a patient's BP is generally monitored intermittently via an upper arm cuff, there may be a delay in the detection of hypotension by the anaesthetist.

OBJECTIVE

The current study investigates whether the presence of continuous BP monitoring leads to improved BP stability.

DESIGN

Randomised, controlled and single-centre study.

PATIENTS: A total of 160 orthopaedic patients undergoing general anaesthesia with a history of chronic hypertension.

INTERVENTION: The patients were randomised to either a study group (n = 77) that received continuous non-invasive BP monitoring in addition to oscillometric intermittent monitoring, or a control group (n = 83) whose BP was monitored intermittently only. The interval for oscillometric measurements in both groups was set to 3 min. After induction of general anaesthesia, oscillometric BP values of the two groups were compared for the first hour of the procedure. Anaesthetists were blinded to the purpose of the study.

MAIN OUTCOME MEASURE: BP stability and hypotensive events.

RESULTS

There was no difference in baseline BP between the groups. After adjustment for multiple testing, mean arterial BP in the study group was significantly higher than in the control group at 12 and 15 min. Mean ± SD for study and control group, respectively were: 12 min, 102 ± 24 vs. 90 ± 26 mmHg (P = 0.039) and 15 min, 102 ± 21 vs. 90 ± 23 mmHg (P = 0.023). Hypotensive readings below a mean pressure of 55 mmHg occurred more often in the control group (25 vs. 7, P = 0.047).

CONCLUSION

Continuous monitoring contributes to BP stability in the studied population.

TRIAL REGISTRATION: NCT02519101.

Для цитирования: Meidert Agnes S, Nold Johanna S, Hornung Roman, Paulus Alexander C, Zwißler Bernhard, Czerner Stephan. The impact of continuous non-invasive arterial blood pressure monitoring on blood pressure stability during general anaesthesia in orthopaedic patients: A randomised trial.. European journal of anaesthesiology. 2017. DOI: 10.1097/eja.0000000000000690.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.