DOI 10.1016/j.jhsa.2018.02.012
Clinical Results of Autogenous Palmaris Longus Tendon Graft for Ruptures of Multiple Extensors in Rheumatoid Hands.
Аннотация
PURPOSE: The purpose of this study was to evaluate the clinical outcome of autogenous palmaris longus grafting for extensor tendon ruptures of 2 or more fingers in rheumatoid hands and to identify the factors related to the clinical outcome.
METHODS
Between 2000 and 2013, a total 41 patients with advanced rheumatoid arthritis and multiple extensor tendon ruptures reconstructed with autogenous palmaris longus tendon grafts were reviewed. Extension lag at the metacarpophalangeal (MCP) joint, total active motion (TAM), and fingertip-to-palm (TTP) distance were evaluated at final follow-up. Simple regression analysis was done to determine the factors predictive of clinical outcome.
RESULTS
The mean extension lag at the MCP joint of the reconstructed finger was 9° (range, 0°-90°; median, 0°). The mean TAM was 239° (range, 85°-280°; median, 260°), and the mean TTP distance was 5 mm (range, 0-50 mm; median, 0 mm). Simple regression analysis showed that only age was related to extension lag at the MCP joint and only arthritis of the MCP joint was related to TAM.
CONCLUSIONS
In rheumatoid arthritis, extensor tendon reconstruction of multiple extensor tendon ruptures using autogenous palmaris longus tendon graft is a viable option to achieve a favorable clinical result.
TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.