Regional anesthesia and pain medicine · 2026
Continuous peripheral nerve blocks for burn management: a retrospective study of outcomes and complications in 281 burn patients.
СтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Perkins Louis, Pedroza Gerardo, Soghikian Max, Santorelli Jarrett E, Haines Laura N, Box Kevin, Lee Jeanne G, Gabriel Rodney, Finneran John J
Аннотация
BACKGROUND: There is scarce literature regarding the use of continuous peripheral nerve blocks in acute burn patients, who may be at higher risk for catheter-related complications, including infection. We sought to describe our center's experience and infection rate with continuous perineural catheters in the setting of pain management for patients suffering from burns.
METHODS: A retrospective observational study was performed including all patients admitted to an American Burn Association-verified regional burn center between January 2018 and July 2023 who received a continuous peripheral nerve block for an acute burn injury.
RESULTS: There were 281 patients in the study cohort who received 484 perineural catheters. The cohort was 52% men with a median age of 39 years (IQR 30-55). A catheter-associated infection, defined as a clinical diagnosis by the treating physicians requiring the need for treatment with antibiotics or surgical debridement, was identified in six perineural catheters (1.2%, 95% CI 0% to 2.2%) involving six different patients (2.1%, 95% CI 0% to 3.8%). The median total body surface area burned was 5% (IQR 2-9%) and 20% of patients had full-thickness burns. The most commonly used catheters were infraclavicular (49%), popliteal sciatic (29%), femoral (19%), and adductor canal (17%). One-third (33%) of patients did not require operating room debridement as the block provided sufficient analgesia for bedside debridement. The median duration of catheter use was 6 days (IQR 4-8). There were no documented cases of nerve injury or toxicity, vascular injury, or local anesthetic systemic toxicity.
CONCLUSIONS: In our practice, continuous perineural catheters in the setting of acute burns are associated with an infection rate comparable to other surgical populations.
METHODS: A retrospective observational study was performed including all patients admitted to an American Burn Association-verified regional burn center between January 2018 and July 2023 who received a continuous peripheral nerve block for an acute burn injury.
RESULTS: There were 281 patients in the study cohort who received 484 perineural catheters. The cohort was 52% men with a median age of 39 years (IQR 30-55). A catheter-associated infection, defined as a clinical diagnosis by the treating physicians requiring the need for treatment with antibiotics or surgical debridement, was identified in six perineural catheters (1.2%, 95% CI 0% to 2.2%) involving six different patients (2.1%, 95% CI 0% to 3.8%). The median total body surface area burned was 5% (IQR 2-9%) and 20% of patients had full-thickness burns. The most commonly used catheters were infraclavicular (49%), popliteal sciatic (29%), femoral (19%), and adductor canal (17%). One-third (33%) of patients did not require operating room debridement as the block provided sufficient analgesia for bedside debridement. The median duration of catheter use was 6 days (IQR 4-8). There were no documented cases of nerve injury or toxicity, vascular injury, or local anesthetic systemic toxicity.
CONCLUSIONS: In our practice, continuous perineural catheters in the setting of acute burns are associated with an infection rate comparable to other surgical populations.