IEEE transactions on bio-medical engineering · 2017
A Methodology for Non-Invasive 3-D Surveillance of Arteriovenous Fistulae Using Freehand Ultrasound.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Colley Eamonn, Carroll John, Thomas Shannon, Varcoe Ramon L, Simmons Anne, Barber Tracie
Аннотация
OBJECTIVE: Surveillance techniques for arteriovenous fistulae are required to maintain functional vascular access, with two-dimensional duplex ultrasound the most widely used imaging modality. This paper presents a surveillance method for an arteriovenous fistula using a freehand three-dimensional (3-D) ultrasound system. A patient-case study highlights the applicability in a clinical environment.
METHODS: The freehand ultrasound system uses optical tracking to determine the vascular probe location, and as the probe is swept down a patient's arm, each B-mode slice is spatially arranged to be post-processed as a volume. The volume is segmented to obtain the 3-D vasculature for high detail analysis.
RESULTS: The results follow a patient with stenosis, undergoing surgery to have a stent placement. A surveillance scan was taken pre-surgery, postsurgery, and at a two-month follow-up. Vasculature changes are quantified using detailed analysis, and the benefits of using 3-D imaging are shown through 3-D printing and visualization.
CONCLUSION AND SIGNIFICANCE: Non-invasive 3-D surveillance of arteriovenous fistulae is possible, and a patient-specific geometry was created using ultrasound and optical tracking. Access to this non-invasive 3-D surveillance technique will enable future studies to determine patient-specific remodeling behavior, in terms of geometry and hemodynamics over time.
METHODS: The freehand ultrasound system uses optical tracking to determine the vascular probe location, and as the probe is swept down a patient's arm, each B-mode slice is spatially arranged to be post-processed as a volume. The volume is segmented to obtain the 3-D vasculature for high detail analysis.
RESULTS: The results follow a patient with stenosis, undergoing surgery to have a stent placement. A surveillance scan was taken pre-surgery, postsurgery, and at a two-month follow-up. Vasculature changes are quantified using detailed analysis, and the benefits of using 3-D imaging are shown through 3-D printing and visualization.
CONCLUSION AND SIGNIFICANCE: Non-invasive 3-D surveillance of arteriovenous fistulae is possible, and a patient-specific geometry was created using ultrasound and optical tracking. Access to this non-invasive 3-D surveillance technique will enable future studies to determine patient-specific remodeling behavior, in terms of geometry and hemodynamics over time.